Association of AI-Assisted Training with Learning Outcomes in Lung Cancer Puncture Ablation: A Retrospective Before-and-After Study.

Yanqiao Ren, Chao Chen, Chenxin Luo, Xuefeng Kan, Guofeng Zhou, Chuansheng Zheng

Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, People's Republic of China. · School of Basic Medical Sciences, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, People's Republic of China.

Observational · n=38

Key points

From the paper's conclusion
  • AI-assisted training was associated with faster acquisition of procedural independence, lower occupational radiation exposure, shorter early procedure times, and fewer selected minor-to-moderate complications, while maintaining comparable ablation efficacy. Because of the retrospective non-randomized before-and-after design, these findings should be interpreted as associations and require confirmation in prospective multicenter studies.

Abstract

BACKGROUND: AI-assisted training has been introduced into interventional radiology education, but its association with learning outcomes in lung cancer puncture ablation remains insufficiently defined. METHODS: This single-center retrospective before-and-after study included 69 early-career interventional physicians who underwent six-month refresher training between January 2020 and December 2024. Trainees were allocated by training period: conventional senior physician-guided training before August 2022 (n=38) and AI-assisted training after implementation of the AI planning/visualization system (n=31). De-identified patient-level ablation outcomes were extracted from the institutional electronic medical database under ethics approval and waiver of written informed consent. RESULTS: Compared with conventional training, AI-assisted training was associated with shorter time to competency (median 43 vs 84 days; absolute difference, -41 days) and fewer supervised cases before independent performance (21 vs 31.5 cases; absolute difference, -10.5 cases). Radiation exposure during training was lower in the AI-assisted group (12.8 ± 2.20 vs 21.1 ± 3.78 mSv; mean difference, -8.3 mSv; approximate 95% CI, -9.7 to -6.9). Initial independent procedure time was also shorter (48.7 ± 8.28 vs 62.2 ± 5.92 min; mean difference, -13.5 min; approximate 95% CI, -17.0 to -10.0). Complete ablation rates were similar (80.7% vs 81.3%). Pneumothorax (5.0% vs 12.5%; risk difference, -7.6 percentage points; approximate 95% CI, -10.1 to -5.1) and hemoptysis (12.7% vs 16.9%; risk difference, -4.2 percentage points; approximate 95% CI, -7.6 to -0.9) were less frequent in the AI-assisted cohort. CONCLUSION: AI-assisted training was associated with faster acquisition of procedural independence, lower occupational radiation exposure, shorter early procedure times, and fewer selected minor-to-moderate complications, while maintaining comparable ablation efficacy. Because of the retrospective non-randomized before-and-after design, these findings should be interpreted as associations and require confirmation in prospective multicenter studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers