From the paper's conclusion- Resting-state BOLD signals in white matter show a spectral elevation near 0.06 Hz on an exponentially decaying background, and white-matter hemodynamic response functions (HRFs) have a prominent initial dip.
Abstract
Resting-state BOLD signals in white matter show a spectral elevation near 0.06 Hz on an exponentially decaying background, and white-matter hemodynamic response functions (HRFs) have a prominent initial dip. We model the resting signal as shot noise: randomly timed neural events are filtered by the HRF, so that the spectrum is the input spectrum multiplied by the squared HRF gain, plus instrumental noise. The initial dip and post-stimulus undershoot remove low-frequency power, making the white-matter HRF a band-pass filter with maximum gain near 0.05 Hz. One set of physiological parameters fits both a measured white-matter HRF (R² = 0.993) and the group-mean white-matter spectrum (R² = 0.987), with a resting transit time of about 4 s and a metabolic response weighted about twice as heavily as in gray matter. Deepening the dip raises the filter gain and moves its maximum toward 0.06 Hz, linking the dip to the spectral feature. A narrower line in individual spectra is reproduced either by an underdamped HRF that matches the measured response over its first 20 s or by a rhythmic input near 0.06 Hz. The model identifies which HRF properties could explain the decline of the peak with age.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Distinct Second Spectral Peak in White Matter BOLD Signals: Mathematical Modeling, Spatial Distribution and Age-Related Evolution.Research square · 2026
- The ballon model revisited.Research square · 2026
- Physics-informed neural networks for subject-specific recovery of travelling-wave structure in resting-state fMRIBIO Web of Conferences · 2026
- Scanner acoustic noise in resting-state fMRI.Magnetic resonance imaging · 2026
- Characterization of the hemodynamic response function in default mode network subregions for task-evoked negative BOLD responses.NeuroImage · 2026
- Characterizing variability in resting-state functional magnetic resonance imaging (rsfMRI) metrics: a normative modeling framework.NeuroImage · 2026