Performance of PI-FAB and TARGET scoring systems in post focal therapy mpMRI surveillance.
J Bradley Mason, Jorge Arias, Bora Kalaycioglu, Aytekin Oto, Alejandro Calvillo Ramirez, Simon Han, Alex Weiss, Haidy Megahed,
Key points
From the paper's conclusion- Conclusion PI-FAB and TARGET scoring systems perform similarly in diagnostic performance, though inter-reader agreement is limited.
Abstract
Background The Prostate Imaging after Focal Ablation (PI-FAB) and Transatlantic Recommendations for Prostate Gland Evaluation with Magnetic Resonance Imaging After Focal Therapy (TARGET) scoring systems have been recently developed to improve detection of post-ablation recurrence of clinically significant prostate cancer (csPCa). However, it is unknown how these two scoring systems compare in clinical practice. Methods Patients who underwent focal therapy (FT) for prostate cancer (PCa) and had post-FT MRI and biopsy were identified from a prospective registry. Post-FT MRIs were reviewed by two radiologists blinded to biopsy results using the PI-FAB and TARGET systems with scores of 3 and ≥ 4, respectively considered positive for csPCa. csPCa recurrence was defined as ≥Gleason 3 + 4 on biopsy. Diagnostic performance metrics including sensitivity/specificity/positive predictive value (PPV)/negative predictive value (NPV)/accuracy were calculated. Area under the receiver operating characteristic curve (AUC) was generated using logistic regression and compared using DeLong's tests. Inter-reader agreement was assessed with Cohen's Kappa (κ). Results 90 patients were eligible. Radiologist #1 showed PI-FAB sensitivity/specificity/PPV/NPV/accuracy/AUC of 67%/82%/54%/89%/78%/74%, respectively; TARGET had values of 67%/79%/50%/88%/76%/73%, respectively. Radiologist #2 showed PI-FAB sensitivity/specificity/PPV/NPV/accuracy/AUC of 62%/68%/42%/83%/66%/65%, respectively; TARGET 62%/68%/42%/83%/66%/66%. Logistic regression showed no difference in AUC for PI-FAB and TARGET (0.69;95%CI:0.59-0.79 vs 0.71;95%CI:0.62-0.80, p = 0.696). Inter-reader agreement was fair for PI-FAB (k = 0.352, p = 0.02) and moderate for TARGET (k = 0.445, p < 0.01). Conclusion PI-FAB and TARGET scoring systems perform similarly in diagnostic performance, though inter-reader agreement is limited. Clinical parameters may be needed to fully assess csPCa recurrence after focal therapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of a ‘stage-gated’ approach for reporting prostate screening MRI: “Is less more?”European Radiology · 2026
- Head-to-head comparison of MRI-based PI-RR scoring system and 68 Ga-PSMA-PET/CT: enhancing prostate cancer recurrence detection after radical prostatectomy.La Radiologia medica · 2026
- PSMA PET Imaging for Prostate Cancer Recurrence After Minimally Invasive Focal Therapy: A Single-Center Retrospective Study.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- Feasibility and early outcomes of salvage robot-assisted radical prostatectomy after focal therapy failure for localized prostate cancer.Translational andrology and urology · 2026
- Multicentre validation of the PRECISE scoring system for prostate MRI during active surveillanceEuropean Radiology · 2026
- [¹⁸F]PSMA-1007 PET/CT in biochemical recurrence after radical prostatectomy: A single-center experience of detection rate and lesion distributionPLoS ONE · 2026