Quantitative assessment of prostate cancer using an individualized apparent diffusion coefficient intensity scale: a proposal.
Michele Scialpi, Giuseppe Nazareno Antogiovanni, Francesco Bianconi, Barbara Palumbo, Guido Bellezza, Martina Mandarano, Saber Ammar, Giovanni Battista Scalera,
Division of Radiology I Santa Maria della Misericordia Hospital, Department of Medicine and Surgery, University of Perugia, Perugia, Italy. · Department of Engineering, University of Perugia, Perugia, Italy.
Key points
From the paper's conclusion- In this retrospective study, the diagnostic performance of an individualized apparent diffusion coefficient (ADC) signal intensity (SI) scale for differentiating prostate cancer (PCa) from benign simplified Prostate Imaging Reporting and Data System (S-PI-RADS) 4 lesions detected on biparametric magnetic resonance imaging (bpMRI) was evaluated.
Abstract
In this retrospective study, the diagnostic performance of an individualized apparent diffusion coefficient (ADC) signal intensity (SI) scale for differentiating prostate cancer (PCa) from benign simplified Prostate Imaging Reporting and Data System (S-PI-RADS) 4 lesions detected on biparametric magnetic resonance imaging (bpMRI) was evaluated. A total of 102 patients with biopsy-confirmed PCa and 79 patients with benign lesions (inflammation, HGPIN, ASAP) presenting as S-PI-RADS 4 were included. An individualized ADC SI scale was generated for each patient using maximum and minimum ADC values from the bladder and femoral head, respectively. The midpoint (ADC_mean) and the percentage difference (PD) between ADC_mean and lesion intensity (ADC_lesion) were calculated. Differences and diagnostic performance were assessed using Mann-Whitney U tests and receiver operating characteristic (ROC) analysis. PCa lesions demonstrated significantly lower ADC values and higher PDs compared with benign lesions (P<0.001). ROC analysis of PD yielded an area under the curve (AUC) of 0.798. Using a PD cut-off of 14.67%, sensitivity and specificity for detecting PCa were 73.5% and 94.9%, respectively. Intra-reader repeatability was high [intraclass correlation coefficient (ICC) 0.92-0.94], and PD values remained robust across variations in ADC fitting. The individualized ADC SI scale provides a patient-specific quantitative measure that effectively distinguishes malignant from benign S-PI-RADS 4 lesions. This approach complements visual bpMRI assessment, demonstrates high specificity, and has the potential to reduce unnecessary biopsies. Further prospective studies are warranted to validate its clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Risk Stratification of Prostate Imaging Reporting and Data System (PI-RADS 3) Lesions in the Peripheral and Transition Zones Using Clinical and Quantitative MRI Markers.Journal of magnetic resonance imaging : JMRI · 2026
- A Quantitative Nomogram Integrating IVIM-derived True Diffusion Coefficient and PSAD for Predicting Clinically Significant Prostate Cancer: Comparison With PI-RADS-based Assessment.Academic radiology · 2026
- Zone-specific diagnostic performance of synthetic MRI quantitative parameters, ADC, and PSA density for clinically significant prostate cancer: comparison with PI-RADS v2.1.International urology and nephrology · 2026
- Comparison of diffusion-relaxation correlation spectrum imaging and conventional quantitative MRI parameters in differentiating between benign prostatic hyperplasia and prostate cancer: A prospective study.Magnetic resonance imaging · 2026
- Correlation of MRI-Derived Apparent Diffusion Coefficient (ADC) Values With Gleason Scores in Prostate Cancer and Quantitative Prostate MRI ReadingCureus · 2026
- Apparent diffusion coefficient-based single-sequence radiomics integrated with clinical variables and Prostate Imaging Reporting and Data System for predicting clinically significant prostate cancer.Translational andrology and urology · 2026