Wang technique: a novel minimally invasive surgical fixation technique for the treatment of pectus excavatum.
Bin Cai, Wenlin Wang, Weiguang Long, Yang Liu, Juan Luo, Shaoyi Zheng, Zian Zeng, Na Li
Institute of the Chest Wall Surgery, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou, China.
Key points
From the paper's conclusion- The Wang technique is effective for the treatment of PE, with a low incidence of bar displacement. It has potential for broader clinical application.
Abstract
BACKGROUND: Pectus excavatum (PE) is the most common thoracic deformity. Currently, the modified Nuss procedure with steel bar implantation is the primary surgical treatment for PE. Traditionally, the bar is fixed using a stabilizer; however, this method is relatively complex and associated with complications. We designed a novel minimally invasive surgical fixation technique (the Wang technique) for the treatment of PE. This study assessed its efficacy and technical characteristics to provide valuable insights into the surgical treatment of PE. METHODS: The clinical data of patients with moderate to severe PE who underwent the modified Nuss procedure with two bars in the Department of Chest Wall Surgery at our hospital between January 2018 and December 2022 were retrospectively analyzed. The data collected included the patients' medical history, severity of PE, imaging findings, operative details, application of the Wang technique, bar retention time, and postoperative complications (e.g., wire breakage and bar displacement). The variables were analyzed to assess the characteristics of the Wang technique. RESULTS: A total of 343 patients were enrolled in this study (299 males and 44 females), including 32 with moderate, 220 with severe, and 91 with extremely severe PE. The Wang technique was used for bar fixation during the surgery. The operative time ranged from 25 to 100 (48.95±15.07) min, and the intraoperative blood loss ranged from 1 to 50 (7.20±5.96) mL. All patients were followed up until bar removal. The bar retention time ranged from 11 to 73 (34.72±6.82) months. Five bars showed displacement (0.73%), occurring in four cases (1.17%), all of which were axial. Additionally, 17 fixation wires were found to be broken (1.00%). All patients were discharged after the successful removal of the bars and fixation wires. No PE recurrence was observed. CONCLUSIONS: The Wang technique is effective for the treatment of PE, with a low incidence of bar displacement. It has potential for broader clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short pectus bars with ventral hinge-point stabilization: clinical outcomes in 160 patients.Frontiers in surgery · 2026
- A percutaneous sternal elevation technique using the Tian-Ping sternal lifter for Nuss repair of pectus excavatum.Journal of thoracic disease · 2026
- Delayed intrathoracic pectus bar displacement after minimally invasive repair of pectus excavatum using the short bar technique: a case series.International journal of surgery case reports · 2026
- Multiple-Bar Repair for Pediatric Pectus Excavatum: A Large Propensity Score-Matched Cohort Study of Safety and Efficacy.Journal of chest surgery · 2026
- PEEK Pectus Bar: Evaluation of a New Material for Pectus Excavatum Repair in Children and Teenagers.Surgical innovation · 2026
- Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.BMC musculoskeletal disorders · 2026