Novel cardiac computed tomography-based preoperative indicator associated with intraoperative graft flow in coronary artery bypass grafting.
Xiaohang Wang, Shen Lin, Wei Feng, Dong Zhao
Division of Cardiovascular Surgery, Department of Surgery, Fuwai Hospital, National Center for Cardiovascular Diseases, Beijing, China.
Key points
From the paper's conclusion- TCAVI as a novel measurement may be useful to appropriately select the optimal target arteries at the time of CABG. It may have clinical potential to predict intraoperative abnormal venous grafts with high accuracy.
Abstract
BACKGROUND: Graft flow in coronary artery bypass grafting (CABG) is linked with blood distribution of the target vessel. In this study, we aimed to develop a novel quantitative measurement of target coronary artery quality using coronary computed tomography angiography (CCTA) and investigate its correlation with intraoperative transit time flow measurement (TTFM). METHODS: We enrolled 68 patients with CABG who underwent preoperative CCTA. Target coronary artery volume index (TCAVI) was calculated from CCTA images and measurements in 65 arterial and 94 venous bypass grafts. CCTA-TCAVI, representing total volume (mm3) of arterial vasculature per individual target artery, was statistically analyzed for correlation with TTFM. RESULTS: CCTA-TCAVI demonstrated a positive correlation with mean graft flow (MGF =0.222, P=0.005). TCAVI was linked with abnormal internal mammary artery (IMA) grafts [intraoperative MGF <20 mL/min and pulsatility index (PI) 5] and saphenous vein grafts (SVGs, <40 mL/min) and PI (5) odds ratio (OR =0.99, <1, P=0.004). Interquartile range (IQR) analysis revealed a significant correlation between abnormal SVG and TCAVI (P<0.001), but no correlation between abnormal IMA and TCAVI (P=0.91). Compared with previous predictive measurements, TCAVI correlated with graft flow(MGF =0.222, P=0.005). The cutoff value for CCTA-TCAVI was 200 mm3. Compared with coronary stenosis percentage, TCAVI prediction accuracy was 13% higher. CONCLUSIONS: TCAVI as a novel measurement may be useful to appropriately select the optimal target arteries at the time of CABG. It may have clinical potential to predict intraoperative abnormal venous grafts with high accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predicting early graft patency using transit-time flow measurement in internal thoracic artery-based composite coronary artery bypass grafting.JTCVS open · 2026
- Outcome-Linked Left Internal Mammary Artery to Left Anterior Descending Artery Graft Flow Threshold and Quantitative Flow Ratio-Based Low-Flow Prediction in Off-Pump Coronary Artery Bypass Grafting.The American journal of cardiology · 2026
- Association of preoperative quantitative flow ratio with 1-year graft patency after coronary artery bypass grafting: A two-center retrospective cohort study.International journal of cardiology · 2026
- Virtual coronary artery bypass grafting.Scientific reports · 2026
- Preoperative Angiographic Washout and Coronary Artery Bypass Graft Patency.JACC. Advances · 2026
- Diagnostic utility of transit time flow measurement for predicting early coronary bypass graft occlusion.JTCVS open · 2026