Perioperative outcomes and quality of life after minimally invasive versus median sternotomy left ventricular assist device implantation: a single-center retrospective cohort study.
Qingpeng Wang, Zhitao Chen, Wenjun Yu, Jie Cai, Hao Tang, Dewen Leng, Wei Wang, Yun Yang,
Department of Cardiovascular Surgery, Zhongnan Hospital of Wuhan University, Hubei Provincial Engineering Research Center of Minimally Invasive Cardiovascular Surgery, Wuhan Clinical Research Center for Minimally Invasive Treatment of Structural Heart Disease, State Key Laboratory of Metabolism and Regulation in Complex Organisms, Wuhan, China. · Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Key points
From the paper's conclusion- MI LVAD implantation is as safe as MS. It maintains equivalent cardiac improvement while offering faster recovery and enhanced postoperative quality of life.
Abstract
BACKGROUND: Left ventricular assist device (LVAD) implantation is an effective destination therapy (DT) for patients ineligible for heart transplantation. While conventional median sternotomy (MS) is widely used, it involves significant surgical trauma, bleeding risk, and delayed recovery, potentially hindering rehabilitation. Minimally invasive (MI) techniques may reduce perioperative complications and enhance long-term quality of life. However, systematic comparisons between MI and MS approaches for LVAD implantation are limited, with scarce data from Chinese populations. This study compares perioperative outcomes, functional recovery, and health-related quality of life between these surgical approaches, providing high-level evidence to inform clinical practice. METHODS: This study included 18 patients who underwent LVAD implantation (MI, n=12; MS, n=6). Preoperative characteristics, intraoperative metrics, postoperative recovery parameters, and complication rates were collected and compared between the two groups. Postoperative quality of life was evaluated with a comprehensive scale integrating generic health status, disease-specific symptoms, and device-related distress. RESULTS: The MI group demonstrated superior perioperative outcomes. Intraoperative blood loss was reduced by nearly 50% (442.5±257.7 vs. 1,733.3±728.5 mL, P<0.001), and mechanical ventilation duration was shorter (5.25±4.33 vs. 27.00±27.18 days, P<0.001) compared to MS. Intensive care unit (ICU) and hospital stays were also shorter. The MI group showed improvements across multiple EuroQol 5-Dimension 5-Level questionnaire (EQ-5D-5L) dimensions, including overall health perception, usual activities, pain/discomfort, and body image distress (P<0.05). CONCLUSIONS: MI LVAD implantation is as safe as MS. It maintains equivalent cardiac improvement while offering faster recovery and enhanced postoperative quality of life.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of Thoracotomy-Based Left Ventricular Assist Device Implantation on Right Ventricular Functional Preservation.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- A Multidimensional Profile of Quality of Life in Patients Living with Long-Term Mechanical Circulatory Support.Journal of clinical medicine · 2026
- Minimally invasive approach versus median sternotomy in patients undergoing surgery for mitral valve infective endocarditis, a meta-analysis.Perfusion · 2026
- Hybrid cardiac rehabilitation in patients with durable left ventricular assist devices: the REHAB-ASSIST study.Frontiers in cardiovascular medicine · 2026
- The impact of minimally invasive mitral valve surgery on early postoperative organ dysfunction.JTCVS open · 2026
- Minimally Invasive Versus Sternotomy in Redo Mitral Valve Surgery: Short- and Long-Term Outcomes with Meta-Regression and Time-to-Event Analysis.Journal of the American Heart Association · 2026