Journal of spine surgery (Hong Kong)

Comparative analysis of autograft vs. synthetic bone graft in spinal fusion: a systematic review and meta-analysis.

Ahmed Onayzan Alshammari, Saadeldin Ahmed Idris, Turki Alhumaidi Dhawi Alshammari, Refal Mohammed Algahtani, Hatim Salem Alanazi, Thayid Binyah Alshammari, Yousef Hulayyil Alanazi, Obaid Muslm Alrashedi,

Department of Orthopaedic Surgery, King Fahad Medical City, Riyadh, Saudi Arabia. · Department of Surgery, College of Medicine, University of Ha'il, Ha'il, Saudi Arabia.

Meta-analysis

Key points

From the paper's conclusion
  • Synthetic bone grafts can be a reliable alternative to autografts in spinal fusion, and the recommendation is weak due to low-certainty evidence. Meanwhile, further longitudinal studies are required to validate these findings.

Abstract

BACKGROUND: Autografts are regarded as the gold standard for spinal fusion owing to their capability to promote bone formation. However, synthetic bone grafts are gaining popularity for their consistency and avoidance of donor site complications. This meta-analysis compares the treatment results of autografts and synthetic bone grafts in spinal fusion procedures and evaluates their clinical effectiveness. METHODS: The study adhered to PRISMA guidelines and conducted a comprehensive literature search. It compared autografts and synthetic bone grafts in spinal fusion by employing a random-effects model for meta-analysis, assessing publication bias, and evaluating the certainty of evidence using Grading, Reporting, Assessment, Development, and Evaluation (GRADE) guidelines, along with methodological quality through the risk of bias-2.0 (RoB-2.0) and Risk of Bias in Non-randomized Studies of Interventions (ROBINS-I) tools. RESULTS: Following a thorough screening, nine studies fulfilled the inclusion criteria. In the subgroup analysis, the pooled effect size for the fusion rate between different types of synthetic bone graft [ceramics, i-Factor, demineralized bone matrix (DBM)] and compared with autograft was 1.24 odds ratio (OR) [95% confidence interval (CI): 0.77-2.02; P=0.38; I2=0%], success rate for ceramics, i-Factor, and bioactive glass was 1.78 OR (95% CI: 1.28-2.48; P=0.0006; I2=0%). The blood loss had an -0.88 standardized mean difference (SMD) (95% CI: -1.90 to 0.15; P=0.09; I2=87%). For reoperation, the effect size was 0.78 (95% CI: 0.37-1.68; P=0.53; I2=0%), and in the complications subgroup analysis (i-Factor, ceramic, bioactive glass), the pooled effect size was 0.82 (95% CI: 0.54-1.24; P=0.35; I2=0%). A funnel plot revealed publication bias, while most studies demonstrated minimal risk of bias. However, the certainty of evidence was low because of this bias and wide variance. CONCLUSIONS: Synthetic bone grafts can be a reliable alternative to autografts in spinal fusion, and the recommendation is weak due to low-certainty evidence. Meanwhile, further longitudinal studies are required to validate these findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers