Electrocautery-assisted Pacemaker Lead Extraction: A Comparative Evaluation of Cutting Versus Coagulation Modes on a Porcine Muscle Model with Clinical Translation.
Malugari Anish Reddy, Daljeet Kaur Saggu, Muthiah Subramanian, Sachin Yalagudri, Dinakar Bootla, Sridevi Chennapragada, Prabhakar Reddy, C Narasimhan
Department of Cardiac Sciences, AIG Hospitals, Hyderabad, India. · Department of Cardiology, All India Institute of Medical Sciences, Hyderabad, India.
Key points
From the paper's conclusion- These findings suggest that the coagulation mode of EE offers a safer and more controlled technique for lead tip extraction.
Abstract
The increasing use of cardiac implantable electronic devices has led to a rise in transvenous lead extractions (TLEs). The most common indications for TLE are infections and lead malfunction. Over time, leads develop fibrotic encapsulation that makes extraction difficult and increases the risk of myocardial injury. Given the thin myocardial wall, particularly in the right atrial appendage and right ventricular apex, the use of advanced powered tools near the lead tip is contraindicated, posing additional challenges. Electrosurgical energy (EE) has been explored as an adjunct to manual extraction to facilitate safe lead tip removal. This study compares the efficacy and safety of cut and coagulation modes of EE using a porcine tissue model and reports its clinical application in a human case. In the porcine model, the cut mode achieved rapid separation of the lead tip but resulted in deeper tissue penetration. In contrast, the coagulation mode (fulguration setting) enabled controlled dissection with minimal depth of penetration without any collateral injury. The application of the coagulation mode during an actual lead extraction with a dwell time of 8 years in a human patient resulted in complete removal with no postoperative complications. These findings suggest that the coagulation mode of EE offers a safer and more controlled technique for lead tip extraction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preclinical and benchtop evaluation of a dedicated tool for insertable cardiac monitor explantation.Heart rhythm O2 · 2026
- Transvenous lead removal only with manual traction without extraction tools.Acta cardiologica · 2026
- Safety and Outcomes of Transvenous Lead Extraction of Advisory ePTFE-Coated Implantable Cardioverter-Defibrillator Leads: A Multicenter Experience With RELIANCE G.JACC. Clinical electrophysiology · 2026
- Assessing the role of transesophageal echocardiography in transvenous lead extraction: is it still essential?European Heart Journal · 2026
- Transvenous Lead Extraction Using a Stepwise Bailout Strategy: A Single-Center Experience with Wrap-Around Rescue in Selected Bailout Cases.Journal of clinical medicine · 2026
- Transvenous Lead Extraction Without Dedicated Surgical Back up in Low-Risk Patients.Heart rhythm · 2026