Do synthetic absorbable sutures cause less uterine tissue reactions than catgut in bovine caesarean sections?
Tom Woods
University of Edinburgh United Kingdom.
Key points
From the paper's conclusion- There is limited evidence concerning the difference in uterine tissue reactions caused when using catgut or a synthetic uterine suture material in bovine caesarean surgeries. The lack of comparability between the relevant studies in terms of population characteristics and type of suture material used (chromic and plain catgut) does not allow a clear conclusion to be made. In addition, uterine adhesion formation is likely to be multifactorial and there is no overall clear indication that the use of synthetic absorbable suture materials is superior in terms of reduced uterine tissue reactions. There are several other papers of interest which may provide further evidence, but these are not available in English and are therefore outside the scope of this Knowledge Summary. How to apply this evidence in practice The application of evidence into practice should take into account multiple factors, not limited to: individual clinical expertise, patient's circumstances and owners' values, country, location or clinic where you work, the individual case in front of you, the availability of therapies and resources.Knowledge Summaries are a resource to help reinforce or inform decision making. They do not override the responsibility or judgement of the practitioner to do what is best for the animal in their care.
Abstract
PICO QUESTION: In bovines undergoing caesarean section does the use of synthetic absorbable uterine sutures compared with catgut result in less uterine tissue reactions? CATEGORY OF RESEARCH: Treatment. NUMBER AND TYPE OF STUDY DESIGNS REVIEWED: Three studies were critically appraised. Two were non-randomised controlled trials and one was a randomised controlled trial. STRENGTH OF EVIDENCE: Weak. OUTCOMES REPORTED: One study found no difference in the incidence of uterine adhesions between plain catgut and polyglactin 910. Two other studies, which were both conducted on the same group of animals using chromic catgut and polyglycolic acid (PGA), demonstrated a lower incidence and severity of uterine adhesions, as well as reduced histopathological indicators of uterine tissue damage, with polyglycolic acid sutures compared to chromic catgut. CONCLUSION: There is limited evidence concerning the difference in uterine tissue reactions caused when using catgut or a synthetic uterine suture material in bovine caesarean surgeries. The lack of comparability between the relevant studies in terms of population characteristics and type of suture material used (chromic and plain catgut) does not allow a clear conclusion to be made. In addition, uterine adhesion formation is likely to be multifactorial and there is no overall clear indication that the use of synthetic absorbable suture materials is superior in terms of reduced uterine tissue reactions. There are several other papers of interest which may provide further evidence, but these are not available in English and are therefore outside the scope of this Knowledge Summary. How to apply this evidence in practice The application of evidence into practice should take into account multiple factors, not limited to: individual clinical expertise, patient's circumstances and owners' values, country, location or clinic where you work, the individual case in front of you, the availability of therapies and resources.Knowledge Summaries are a resource to help reinforce or inform decision making. They do not override the responsibility or judgement of the practitioner to do what is best for the animal in their care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of intra-abdominal adhesions formation following implantation of synthetic, biosynthetic, and biologic meshes in a rat model.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2026
- Evaluation of polymeric films and streptokinase for prevention of postoperative intra-abdominal adhesion in rabbits.Acta cirurgica brasileira · 2026
- The Use of Bovine Teeth as an Experimental Substrate in the Evaluation of Shear in Contemporary Adhesive Systems.Polymers · 2026
- Clinical Factors Associated With Failure of Uterine Compression Sutures in Postpartum Hemorrhage During Cesarean Delivery: A Systematic Review.Cureus · 2026
- Absorbable Versus Non-Absorbable Suture Materials in Transtibial Pull-Out Repair of Medial Meniscus Posterior Root Tears: A Systematic Review and Meta-Analysis.Orthopaedics & traumatology, surgery & research : OTSR · 2026
- Long-term gynecological symptoms and ultrasound and reproductive outcomes after monofilament vs multifilament uterine closure at Cesarean delivery: secondary analysis of randomized controlled trial.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2026