TouchREVIEWS in endocrinology

Knowledge, attitude and practice on continuous glucose monitoring and self-monitoring of blood glucose among healthcare professionals across India: A cross-sectional study.

Nitin Kapoor, Shehla Sheikh, Sambit Das, Navneet Agarwal, Mukut Roy, Sanjay Kalra

Department of Endocrine, Diabetes & Metabolism, Christian Medical College, Vellore, India. · Department of Endocrinology, KGN Diabetes and Endocrine Center, Mumbai, India.

Observational

Key points

From the paper's conclusion
  • The study highlights the adoption-action gap of CGM use in diabetes care in Indian settings; however, the predominantly experienced, private-sector sample may limit generalizability to the broader HCP population. High costs, variable confidence in CGM interpretation and continued reliance on SMBG contributed to the gap despite HCPs' strong awareness of CGM's clinical value. Addressing these barriers and improving training may enhance CGM adoption nationwide.

Abstract

BACKGROUND: Uncontrolled glycemia remains a major concern in India, underlining the need for wider adoption of effective glucose monitoring methods in diabetes care. Despite the benefits of continuous glucose monitoring (CGM), its adoption remains low in India and is unevenly distributed across healthcare settings and patient populations. METHODS: A cross-sectional, questionnaire-based survey was conducted among healthcare professionals (HCPs) practicing across private and public healthcare settings in India to assess their knowledge, attitudes and practices regarding CGM metrics using an 18-item questionnaire. Responses were measured using a 5-point Likert scale. RESULTS: A total of 126 HCPs from different specialties participated in the study. Most HCPs (81.7%) expressed confidence in the use of CGM in patients with gestational diabetes mellitus. The majority of HCPs were confident or highly confident in interpreting CGM reports (80.1%) and explaining them to patients (81.8%). More than 90% of HCPs agreed that CGM improves overall diabetes management and 88.1% were confident that CGM helps reduce hypoglycemic and hyperglycemic episodes compared with self-monitoring of blood glucose (SMBG) alone. Most HCPs (78.6%) agreed that the cost of CGM is a major barrier to its wider adoption in diabetes care. Despite recognizing the clinical value of CGM, fewer than half of HCPs believed it could completely replace SMBG. CONCLUSION: The study highlights the adoption-action gap of CGM use in diabetes care in Indian settings; however, the predominantly experienced, private-sector sample may limit generalizability to the broader HCP population. High costs, variable confidence in CGM interpretation and continued reliance on SMBG contributed to the gap despite HCPs' strong awareness of CGM's clinical value. Addressing these barriers and improving training may enhance CGM adoption nationwide.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Knowledge, attitude and practice on continuous glucose monitoring and self-monitoring of blood glucose among healthcare professionals across India: A cross-sectional study — Science Skim