microPublication biology

The limit of detection of a Phytophthora agathidicida LAMP assay is higher under alternative laboratory conditions.

Jade Tt Palmer, Monica L Gerth

School of Biological Sciences, Victoria University of Wellington, New Zealand.

Key points

From the paper's conclusion
  • We evaluated its analytical robustness using the same master mix on an alternative platform (QuantStudio 3), and separately tested an alternative NEB master mix.

Abstract

Surveillance of Phytophthora agathidicida , the causal agent of kauri dieback, has included soil baiting followed by loop-mediated isothermal amplification (LAMP)-based detection. This approved assay was reported to detect 1 fg of DNA using OptiGene Isothermal Master Mix on a BioRanger instrument. We evaluated its analytical robustness using the same master mix on an alternative platform (QuantStudio 3), and separately tested an alternative NEB master mix. Both assays yielded a reliable detection limit of 1,000 fg, with variable detection at 100 fg and none below. Diagnostic laboratories should verify assay performance under their operational conditions prior to implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers