Journal of dental hygiene science

Effect of Handle Design on Fatigue Development and Resolution in Dental Hygienists: Clinical Implications.

Susan Meishan Yang, Kairong Lin, Winston Kimball Doud, Cherie Yvette Wink, Jae Kyung Shim, Beatricia Wu Lam, Benjamin Emerson Dolan, Petra Wilder-Smith

Beckman Laser Institute and Medical Clinic, University of California Irvine School of Medicine, Irvine, CA 92612, USA. · San Joaquin Valley College School of Dental Hygiene, Ontario, CA 91764, USA.

Randomised

Key points

From the paper's conclusion
  • Thirty-second breaks are inadequate for full neuromuscular recovery even after only 2 minutes of scaling. As the typical prophylaxis appointment lasts 30∼60 minutes, additional studies are needed to develop effective rest protocols to support neuromuscular recovery in healthy hygienists, and also in those with MSDs. An ergonomic adaptive handle design can reduce and support quicker recovery from muscle fatigue. Instrument selection is an important variable in maintaining a clinician's neuromuscular health and clinical performance.

Abstract

BACKGROUND: Musculoskeletal disorders (MSDs) affect most dental hygienists. While advances in design can reduce the biomechanical strain associated with instrumentation, the literature offers little guidance on rest-break parameters, or on how instrument design may modify those requirements. Goal was to map the effect of rigid vs adaptive handle design on fatigue development and resolution related to dental scaling. METHODS: This study featured a crossover design in which 20 dental hygienists completed two study arms, each consisting of four 2-minute scaling intervals separated by 30-second breaks, followed by 30 minutes of monitored rest. One study arm was completed using an adaptive silicone-over-steel curette, the other tested a rigid stainless-steel curette. The order of instrument use was randomized. Surface electromyography (sEMG) recorded muscle activity continuously in 4 muscles (abductor pollicis brevis, first dorsal interosseous, flexor pollicis longus, and extensor digitorum communis) through active intervals and rest periods. Linear mixed-effects models were used to test the primary sEMG outcome, with Bonferroni-corrected post-hoc comparisons. Recovery time was compared by Wilcoxon signed-rank test; Significance was set at p<0.05. RESULTS: Over the course of scaling, muscle activity increased significantly more with the rigid curette vs. the adaptive (p<0.0001; η2=0.46). Each 30-second break achieved 24∼28% recovery towards baseline levels of muscle activity with the rigid curette vs. 39∼44% with the adaptive curette. By the end of the 30-minute monitored recovery period, muscle activity remained 13.9% above baseline for the rigid curette vs. 4.6% for the adaptive. The amount of time needed to recover to baseline levels of muscle activity was significantly quicker for the adaptive curette (155 seconds) vs. the rigid (295 seconds) (p=0.0003, r=0.61). CONCLUSION: Thirty-second breaks are inadequate for full neuromuscular recovery even after only 2 minutes of scaling. As the typical prophylaxis appointment lasts 30∼60 minutes, additional studies are needed to develop effective rest protocols to support neuromuscular recovery in healthy hygienists, and also in those with MSDs. An ergonomic adaptive handle design can reduce and support quicker recovery from muscle fatigue. Instrument selection is an important variable in maintaining a clinician's neuromuscular health and clinical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers