Journal of the American Society of Nephrology : JASN

Quantum Dot-Based Fluorescent Lateral Flow Immunoassay Strip for Rapid Detection of Anti-nephrin Autoantibodies in Idiopathic Nephrotic Syndrome.

Mingyu Lai, Rui Gu, Jiayi Shen, Tong Shao, Baohua Yang, Jianhua Mao, Qing Ye

The First Clinical Medicine College of Lanzhou University, Lanzhou 730030, China. · Department of Pediatrics, and Department of Nephrology, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Children and Adolescents' Health and Diseases, Hangzhou 310052, China.

Key points

From the paper's conclusion
  • These findings suggest that the QD-LFIA enabled rapid detection of anti-nephrin autoantibodies in children with idiopathic nephrotic syndrome. The QD-LFIA showed good agreement with IP-WB and identified additional anti-nephrin-positive samples undetected by IP-WB.

Abstract

BACKGROUND: Idiopathic nephrotic syndrome is a common primary glomerular disease in children. Circulating anti-nephrin autoantibodies have emerged as clinically relevant biomarkers, but existing detection methods are complex and time-consuming. We developed a quantum dot microsphere-based lateral flow immunoassay (QD-LFIA) for rapid serum anti-nephrin autoantibody detection. METHODS: Quantum dot microspheres were conjugated to recombinant human nephrin protein, and the reading time, T-line coating concentration, and nephrin protein labeling amount were optimized. Analytical performance was evaluated by receiver operating characteristic (ROC) analysis based on test line/control line ratios generated by the dry fluorescence immunoanalyzer, together with interference and accelerated stability testing. Clinical performance was assessed in 191 pediatric serum samples, with qualitative QD-LFIA results compared against immunoprecipitation-Western blotting (IP-WB). Discordant samples were evaluated by recombinant nephrin protein inhibition assay. Clinical indices were compared between anti-nephrin autoantibody positive and negative patients. RESULTS: The optimized reaction time, T-line coating concentration, and recombinant nephrin protein labeling amount were 10 min, 0.5 mg/mL, and 92.4 μg, respectively. ROC analysis yielded an AUC of 0.90 (95% CI 0.84-0.97), with 93% sensitivity and 92% specificity at a test line/control line cutoff of 0.003. The QD-LFIA resisted the tested interferents and maintained stable performance for 40 days at 37 °C. QD-LFIA achieved overall, positive, and negative percent agreements of 92%, 89%, and 93%, respectively, relative to IP-WB. Recombinant nephrin protein inhibition abolished the signals in all 12 QD-LFIA-positive/IP-WB-negative samples. Anti-nephrin autoantibody positive patients had higher 24-h urinary protein excretion and lower serum albumin levels than negative patients. CONCLUSIONS: These findings suggest that the QD-LFIA enabled rapid detection of anti-nephrin autoantibodies in children with idiopathic nephrotic syndrome. The QD-LFIA showed good agreement with IP-WB and identified additional anti-nephrin-positive samples undetected by IP-WB.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers