Comparative evaluation of RANKL and OPG levels in gingival crevicular fluid and saliva during orthodontic treatment using thermoformed and direct-printed aligners.
Pooja Lakshmanan, Shivakumar Baskaran, Swarna Alamelu, Karthick Baskar
Ragas Dental College and Hospital, Department of Periodontics (Tamil Nadu, India).
Key points
From the paper's conclusion- Aligner types elicited biomarker responses consistent with bone remodeling. Direct-printed aligners demonstrated a trend toward a more stable, OPG-dominant biological response. These findings should be interpreted cautiously, due to the pilot nature of the study. Saliva correlated with GCF, supporting its use as a non-invasive biomarker source. Larger longitudinal studies are warranted.
Abstract
INTRODUCTION: Orthodontic tooth movement (OTM) is regulated by alveolar bone remodeling through the receptor activator of nuclear factor kappa-B ligand (RANKL) and osteoprotegerin (OPG) axis. Clear plastic aligners (CPAs), available as thermoformed and direct-printed variants, differ in force delivery and material properties, influencing biomarker responses. OBJECTIVE: This prospective pilot randomized study compared salivary and gingival crevicular fluid (GCF) levels of RANKL and OPG during treatment with thermoformed and direct-printed aligners, and evaluated correlations between saliva and GCF. MATERIAL AND METHODS: Eight healthy adults (18-40 years) requiring orthodontic treatment were randomly assigned to thermoformed or direct-printed aligners. GCF and unstimulated saliva were collected at baseline and at 1, 2, 3, 4, and 6 weeks. RANKL and OPG were quantified using ELISA, and data were analyzed with SPSS v21.0 (IBM, USA). RESULTS: Thermoformed aligners exhibited a peak in GCF RANKL at 3 weeks, followed by a decline at 6 weeks. Direct-printed aligners showed a gradual reduction, with significantly lower RANKL at 4 and 6 weeks (p < 0.05). OPG levels were consistently higher in the direct-printed group across all time points in saliva and GCF (p < 0.05). Salivary OPG strongly correlated with GCF OPG at baseline, 3, and 6 weeks, while RANKL correlations were higher during later treatment phases. CONCLUSION: Aligner types elicited biomarker responses consistent with bone remodeling. Direct-printed aligners demonstrated a trend toward a more stable, OPG-dominant biological response. These findings should be interpreted cautiously, due to the pilot nature of the study. Saliva correlated with GCF, supporting its use as a non-invasive biomarker source. Larger longitudinal studies are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of different clear aligner systems with fixed orthodontic treatment in terms of endocrine-disrupting monomer release, treatment effectiveness and efficiency : An in vivo randomized clinical trial.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2026
- Time-dependent changes in gingival crevicular fluid volume during orthodontic tooth movement with clear aligners and fixed appliances.Clinical oral investigations · 2026
- The Use of Salivary and Gingival Crevicular Fluid Biomarkers in Predicting Orthodontic Treatment ResponseClinical Cosmetic and Investigational Dentistry · 2025
- Salivary biomarkers during en-masse retraction into recent and healed extraction sites: A randomised controlled trial.Journal of orthodontics · 2026
- Fit analysis of 3D-printed versus thermoformed clear aligners for labial tooth movement using micro-CT: an in vitro studyScientific Reports · 2026
- Dynamic changes in NLRP3 and HMGB1 expression and their clinical significance during combined periodontal-orthodontic treatmentFrontiers in Immunology · 2026