Safe Surgery Checklist for robotic surgery: implementation of best practices.
Gisele Passos Cabral Benjamim, Andressa Borges Trindade da Silva Araujo, Igor Medeiros Cruz, Ana Paula Vantil, Nathalia Roberta Azevedo Dias, Ana Beatriz Martins Gomes, Carolina Silva Liquieri Vaz, Thalita Gomes Do Carmo
Universidade do Estado do Rio de Janeiro, Faculdade de Enfermagem, Hospital Universitário Pedro Ernesto. Rio de Janeiro, RJ, Brasil. · Universidade Federal Fluminense, Escola de Enfermagem Aurora de Afonso Costa. Niterói, RJ, Brasil.
Key points
From the paper's conclusion- The implementation of the checklist contributed to improving intraoperative care processes, particularly regarding the prevention of injuries related to surgical positioning and ensuring the availability of materials for surgical conversion, among other measures.
Abstract
OBJECTIVE: To implement and evaluate the effectiveness of a safe surgery checklist for robotic surgery, based on best available evidence. METHOD: A quasi-experimental before-and-after study conducted based on the JBI best practice implementation framework. The study was carried out between 2022 and 2024 in a university hospital in the city of Rio de Janeiro, with the participation of nine nurses from the robotic surgery team. Care practices were evaluated by analyzing the medical records of 90 patients who underwent robotic surgery. The study comprised three stages articulated with seven operational phases: context analysis, facilitation of change, and process evaluation. The analysis was guided by 18 criteria derived from the JBI evidence summary and complemented by an integrative review. RESULTS: In the baseline audit, 17 of the 18 criteria (94.4%) showed noncompliance, including the absence of checks for robotic supplies, materials for surgical conversion, skin assessment at the end of the procedure, and postoperative guidance. After the development and implementation of the specific checklist, combined with training, 16 of the 18 criteria (88.9%) achieved compliance rates equal to or greater than 80% in the follow-up audit. Two criteria dependent on the medical team required additional strategies; in the second audit, communication about critical periods reached 83.3% compliance and time monitoring in procedures lasting three to four hours reached 70.6% among eligible cases. CONCLUSION: The implementation of the checklist contributed to improving intraoperative care processes, particularly regarding the prevention of injuries related to surgical positioning and ensuring the availability of materials for surgical conversion, among other measures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An intra-operative checklist for low-impact robotic urologic surgery: a three-round J-ERUS/YAU Delphi consensus.Journal of robotic surgery · 2026
- Improving Compliance With the World Health Organization Surgical Safety Checklist Through a Clinical Audit at Prince Osman Digna Hospital, SudanCureus · 2026
- Patient safety culture, teamwork, and observed perioperative safety compliance in a high-volume surgical unitmedRxiv · 2026
- Surgical Safety Checklist Implementation in a Tunisian University Hospital: A Mixed-Methods Study of Compliance and Nurses' Perspectives on Barriers, Facilitators, and Sustainability.Journal of nursing management · 2026
- Expert consensus on robotic colorectal surgery proctoring in the UKColorectal Disease · 2026
- Compliance With the World Health Organization Surgical Safety Checklist in the Operating Room at the National Referral Hospital, Bhutan: A Cross-Sectional Quality Assessment.Journal of patient safety · 2026