Torque expression in conventional and self-ligating orthodontic brackets: An in vitro study.
Martha de Abreu Avila, José Guilherme Neves, Américo Bortolazzo Correr, Milton Santamaria-Junior, Eduardo Almada, Lourenço Correr-Sobrinho, Ana Rosa Costa
Department of Orthodontics, Fundação Hermínio Ometto - FHO, Araras, SP, Brazil. · Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, UNICAMP, State University of Campinas, Piracicaba, SP, Brazil.
Key points
From the paper's conclusion- Overall, torque expression was influenced more by the dimensional characteristics of brackets and rectangular archwires than by the type of ligature used.
Abstract
This study assessed torque expression at different angulations of conventional, interactive, and passive self-ligating brackets, with or without metal ligatures, and evaluated surface morphology and chemical composition (%). All brackets (Roth prescription, 0.022" x 0.028" slot) were fixed to round acrylic cylinders with cyanoacrylate adhesive. Five hundred segments of rectangular archwires (0.019" x 0.025") were bent and welded (20 mm x 10 mm), then fixed to the brackets either with or without 0.010" metal ligatures in ten experimental groups (n = 10). The assembled specimens were then mounted on a universal testing machine, and a vertical force was applied to the free end of the archwire, resulting in a 10 mm displacement. Mean torque values (N·mm) at specified torque angles of 0° to 25°, as well as the mean torque angles (°) corresponding to 5 and 20 N·mm, were analyzed using ANOVA and Tukey's test (α = 0.05). Bracket design and chemical composition were examined by SEM/EDS. Slot angulation and dimensional measurements were evaluated using ImageJ. Passive self-ligating brackets, without and with ligatures, showed the smallest torque angles, statistically smaller than those of the other groups (p < 0.001). Bracket clips were composed predominantly of nickel and titanium. Passive self-ligating brackets, either ligated or not, showed the highest torque expression at both 5 and 20 N·mm. Overall, torque expression was influenced more by the dimensional characteristics of brackets and rectangular archwires than by the type of ligature used. Clinically, passive self-ligating brackets may facilitate earlier torque expression during orthodontic treatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- Influence of Mastication on Orthodontic Wire Sliding in Nickel-Titanium Brackets with Superelastic Wings.Journal of functional biomaterials · 2026
- Effect of Metal Primer Application on the Shear Bond Strength of Orthodontic Brackets with Different Base Designs: An In Vitro Study.Dentistry journal · 2026
- Comparison of Mechanical Characteristics of Three Different Types of Wires for Bonded Lingual Retainer Fabrication.Journal of dentistry (Shiraz, Iran) · 2026
- Treatment outcomes, efficiency and complications of customized ceramic brackets compared with conventional fixed orthodontic appliances.The Angle orthodontist · 2026
- Programmed Tooth Movement With and Without Composite Attachments in Clear Aligner Therapy: A Systematic Review of Finite Element Analysis (FEA).Bioengineering (Basel, Switzerland) · 2026