◆ Hospital pediatrics2026-09-14

Neonatal Capillary Blood Sampling Procedure: A Scoping Review.

Janene Douglas, Deanne August, Jacqueline Cunninghame, Natasha Roberts

一句话结论 · In one sentence

Inconsistent reporting on procedural elements and device use impedes procedural best-practice evolution and should be a priority of future research.

原始摘要(英文原文)· Original abstract
BACKGROUND: Neonatal capillary blood sampling is common and painful, but procedural elements (eg, warming) appear inconsistent, with the impact on sampling effectiveness and procedural best practice unclear. OBJECTIVE: To identify existing procedural practices and knowledge gaps to inform best practice for neonatal capillary blood sampling and guide procedural use in future research. METHODS: The Joanna Briggs Institute methodology was used, with sources including peer-reviewed articles between 2005 and 2025 from PubMed, CINAHL Complete (EBSCO host), and Cochrane Library, focused on the neonatal population. Screening was completed in Covidence by 2 independent authors (third for conflicts) and extracted into Airtable with results reported descriptively. RESULTS: Of the 2846 articles identified, 73 met criteria, originating predominantly from the European region (n = 36). Most were randomized controlled trials (n = 47), followed by observational studies (n = 9) and expert opinion (n = 6). Primary outcomes reported (n = 63/73) were predominantly pain assessments (n = 46) and blood sample quality (n = 14). Procedural practices were inconsistently reported across articles-eg, decontamination (33/73 [45%]), supportive care (38/73 [52%]), and lancing device type used (40/73 [55%]). Within articles reporting roles (n = 60/73), nurses/midwives were commonly the proceduralist (n = 30 [50%]), followed by a comforter role (n = 14 [23%]), in addition to parents (n = 20 [33%]). Successful procedural characteristics (12/73) were reported as (1) sufficient blood (1 puncture/incision; n = 5), (2) minimal squeezing/free-flowing blood droplets (n = 3), (3) no hemolysis/adequate blood (n = 2), (4) no hemolysis/free-flowing blood (n = 1), and (5) minimal squeezing/procedure time (n = 1). CONCLUSION: Inconsistent reporting on procedural elements and device use impedes procedural best-practice evolution and should be a priority of future research.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Neonatal Capillary Blood Sampling Procedure: A Scoping Review. — 科研速览 Science Skim