Pharmacodynamic Equivalence and Safety of Budesonide/Glycopyrrolate/Formoterol Fumarate With a Next-Generation Propellant Versus Hydrofluoroalkane-134a Propellant: A Randomized Phase 3 Study in Chronic Obstructive Pulmonary Disease.

Matthew Camiolo, Hitesh Pandya, Mandeep Jassal, Artur Bednarczyk, Yubo Tan, Margareta Puu, David Petullo, Patrik Bondarov,

Respiratory and Immunology, Clinical Development, BioPharmaceuticals R and D, AstraZeneca, Boston, Massachusetts, United States. · Respiratory and Immunology, Clinical Development, BioPharmaceuticals R and D, AstraZeneca, Cambridge, United Kingdom.

Randomised · Phase III · n=296

Key points

From the paper's conclusion
  • Findings support the switch from HFA-134a to HFO-1234ze in BGF pMDIs.

Abstract

BACKGROUND: To understand the efficacy, safety, and tolerability of the budesonide/glycopyrrolate/formoterol fumarate (BGF) pressurized metered-dose inhaler (pMDI) with the next-generation propellant hydrofluoroolefin-1234ze (HFO-1234ze), a propellant with substantially lower global warming potential, versus hydrofluoroalkane-134a (HFA-134a). METHODS: This randomized, 3-way crossover study (NCT06075095) assessed pharmacodynamic equivalence and safety of BGF HFO-1234ze versus BGF HFA-134a in participants with chronic obstructive pulmonary disease. Participants received twice-daily doses for 4 weeks in 3 consecutive treatment periods: A) BGF HFO-1234ze 320/18/9.6 μg, B) BGF HFA-134a 320/18/9.6 μg, and C) placebo HFA-134a in 1 of 6 randomized sequences. Two lung function endpoints (change from baseline in post-dose FEV1 area under the curve 0-4h [FEV1 AUC0-4h; primary] and morning pre-dose trough FEV1 [secondary] at Day 29) were assessed. Superiority of BGF HFA-134a versus placebo HFA-134a was assessed to demonstrate assay sensitivity. Propellant equivalence was demonstrated if 2-sided 90% CIs for ratios of BGF HFO-1234ze/BGF HFA-134a for both lung function endpoints were within 0.8-1.25 and 0.7-1.43, respectively. Safety was also assessed. RESULTS: 296 participants were randomized and started treatment. Superiority of BGF HFA-134a versus placebo HFA-134a, and thus, assay sensitivity for the effect of BGF was confirmed for both lung function endpoints (p<0.001). Change from baseline in post-dose FEV1 AUC0-4 and morning pre-dose trough FEV1 at Day 29 were equivalent between BGF HFO-1234ze and BGF HFA-134a (Ratio [90% CI]: 0.94 [0.88, 1.00]; 0.95 [0.84, 1.08], respectively). Adverse events were balanced across treatments. CONCLUSION: Findings support the switch from HFA-134a to HFO-1234ze in BGF pMDIs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Pharmacodynamic Equivalence and Safety of Budesonide/Glycopyrrolate/Formoterol Fumarate With a Next-Generation Propellant Versus Hydrofluoroalkane-134a Propellant: A Randomized Phase 3 Study in Chronic Obstructive Pulmonary Disease — Science Skim