Continuous Glucose Monitoring Reveals Glycemic Profile in Adrenal Insufficiency Patients on Glucocorticoid Replacement.
Cuili Ning, Rui Zhang, Wei Liu, Xianghai Zhou, Yunyang Sun, Xueyao Han, Linong Ji, Qian Ren
Department of Endocrinology, Peking University People's Hospital , Beijing, China. · Shanghai iMedpower Tech.LTD , Beijing, China.
Key points
From the paper's conclusion- Patients with AI receiving glucocorticoid replacement experience more frequent CGM-recorded asymptomatic hypoglycemia and greater glucose variability. CGM may provide valuable insights for optimizing glucocorticoid administration strategies in AI.
Abstract
OBJECTIVE: Hypoglycemia is common in the patients with adrenal insufficiency (AI), who require lifelong glucocorticoid replacement therapy. However, whether this therapy restores physiological glycemic fluctuations in the patients with AI remains unclear. This study aimed to characterize glucose fluctuation pattern in the patients with AI using continuous glucose monitoring (CGM). METHODS: Twenty-seven patients with AI on stable doses of glucocorticoid were consecutively enrolled. Fifty-four age-, sex-, and BMI-matched normal controls (NC) were selected from a healthy volunteer database at a 2:1 ratio. CGM was conducted with a blinded method for 14 days. Glucocorticoid regimen and adverse events during CGM were documented. RESULTS: The AI group had a mean age of 59.53±8.51 years (15 males). Compared with NC, the patients with AI exhibited increased time below range (TBR, glucose <3.9 and <3.0 mmol/L) and decreased time in range (TIR, glucose within 3.9-7.8 mmol/L). Time above range (TAR, glucose ≥7.8 mmol/L) were elevated during the lunch and dinner periods, and glucose fluctuation parameters were also increased. CGM-detected hypoglycemia was observed in all patients (27/27, 100%) versus 46/54 (85.2%) controls (p = 0.047). The patients receiving once-daily glucocorticoid had higher lunchtime TAR than those on twice-daily dosing. Hydrocortisone-treated patients showed higher breakfast and lunchtime TAR compared with prednisone users. Patients with immune checkpoint inhibitors (ICIs) induced AI had higher glucose levels and fluctuation parameters during breakfast and dinner periods than those with other etiologies. CONCLUSIONS: Patients with AI receiving glucocorticoid replacement experience more frequent CGM-recorded asymptomatic hypoglycemia and greater glucose variability. CGM may provide valuable insights for optimizing glucocorticoid administration strategies in AI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous glucose monitoring reveals thyroid feedback-related residual glycemic variability and hypoglycemia during inpatient glucose optimization in euthyroid adults with type 2 diabetes: a CGM-based observational study.BMC endocrine disorders · 2026
- Impact of Hybrid Continuous Glucose Monitoring on Glycemic Control in a Medical Intensive Care Unit.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026
- Use of Continuous Glucose Monitoring Indicators to Guide Dose Titration of Weekly Basal Insulin Efsitora Alfa in Insulin-Naive and Basal Insulin-Experienced Adults with Type 2 Diabetes: A Retrospective Analyis.Diabetes technology & therapeutics · 2026
- Guiding Inpatient Glycemic Management with Continuous Glucose Monitoring. A Prospective Nonrandomized Comparative Cohort Study.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2026
- Postpartum glycemic trends among people with gestational diabetes using continuous glucose monitoring.American journal of obstetrics & gynecology MFM · 2026
- Continuous Glucose Monitoring in Insulin-Treated Older Adults With Diabetes and Alzheimer Disease and Related DementiasJAMA Network Open · 2025