Explaining the Variance in Repetitions-In-Reserve After Low-Load Blood Flow Restricted Resistance Exercise.
Charlie J Davids, Ivana Vasiljevic, Alex Katsifolis, Haresh Suppiah, Lachlan P James, Brendan R Scott
Sport, Performance, and Nutrition Research Group, School of Allied Health, Human Services, & Sport, La Trobe University, Melbourne, Australia. · PHysical Activity, Sport and Exercise (PHASE) Research Group, School of Allied Health, Murdoch University, Murdoch, Australia; and.
Key points
From the paper's conclusion- Explaining the variance in repetitions-in-reserve after low-load blood flow restricted resistance exercise.
Abstract
Davids, CJ, Vasiljevic, I, Katsifolis, A, Suppiah, H, James, LP, and Scott, BR. Explaining the variance in repetitions-in-reserve after low-load blood flow restricted resistance exercise. J Strength Cond Res XX(X): 000-000, 2025-Low-load resistance exercise with blood flow restriction (LL-BFR) is prescribed using standardized protocols (e.g., 30, 15, 15, 15 repetitions at 20-40% 1-repetition maximum). However, considerable variance exists in proximity to muscular failure under these guidelines, potentially affecting the adaptive stimulus. This study aimed to evaluate the variability in LL-BFR performance and identify factors influencing this variance. In addition, the accuracy of a subjective autoregulation strategy was evaluated during LL-BFR. Twenty recreationally active adults (12 men, 8 women) completed a leg press LL-BFR protocol, a local muscular endurance (LME) task, and conditioned pain modulation (CPM) assessments. Results revealed significant interindividual differences in the number of additional repetitions completed beyond the prescribed 15 repetitions in the final set of LL-BFR (19 ± 12, range 4-47). Local muscular endurance capacity (r = 0.63, p = 0.003) and relative CPM response (r = 0.50, p = 0.026) were key predictors of this variance, explaining 56% of the variability. In addition, subjects tended to underestimate repetitions-in-reserve (RIR) during LL-BFR (RIR error: 12 ± 11), reducing the accuracy of subjective autoregulation strategies. These findings suggest that higher LME and greater pain modulation capacity allow individuals to complete more repetitions before failure, resulting in a heterogeneous stimulus when using fixed LL-BFR protocols. Practitioners should consider LME and pain modulation when prescribing LL-BFR and may need to adjust loads or repetitions to ensure proximity to failure. Autoregulation using RIR should be applied cautiously, with predictions made closer to task failure for accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Automated Blood Flow Restriction Device Is Reliable, but Not Valid, for Determining Lower Limb Occlusion Pressure in Resistance-trained Adults.Journal of strength and conditioning research · 2026
- Effects of Blood Flow Restriction Training on Lower Extremity Strength, Power, and Athletic Performance: A Scoping Review.Cureus · 2026
- Acute neuromuscular and short-term recovery responses to low-load exercise with individualized blood flow restriction in elite male volleyball players.Scientific reports · 2026
- Effects of a low-load multi-component training program with blood flow restriction versus the same program without blood flow restriction on muscle thickness and functional outcomes in physically inactive young adults: randomized controlled trialFrontiers in Physiology · 2026
- Influence of blood flow restriction cuff width on acute metabolic, perceptual, and landing responses to low-load resistance exercise in trained long jump athletes.Frontiers in physiology · 2026
- Similar acute increases in muscle size, but discrete perceptual responses to low‐load blood flow restriction protocolsClinical Physiology and Functional Imaging · 2026