Transport Phenomena

Dynamic response of simplex swirl injector to external forcing under supercritical conditions

Boxiao Jin, Weiming Ding, Vigor Yang, Jeong-Yeol Choi

Key points

From the paper's conclusion
  • The dynamic response of a simplex swirl injector of cryogenic fluid to external forcing is numerically investigated under supercritical conditions.

Abstract

The dynamic response of a simplex swirl injector of cryogenic fluid to external forcing is numerically investigated under supercritical conditions. The formulation is based on the full conservation equations and takes into account real-fluid thermodynamics and transport. Liquid oxygen at 120 K is injected tangentially into the injector and discharged into gaseous oxygen at 300 K and 10 MPa. Sinusoidal perturbations are imposed on the inlet mass flow rate over a frequency range of 0.5–14 kHz. The calculated mass transfer function, defined as the ratio of the mass flow-rate fluctuation at the injector exit to that at the inlet, strongly depends on the forcing frequency. The response function in the frequency domain first increases, reaches a maximum value, and then decays to zero asymptotically. The maximum response occurs at the frequency of 1.9 kHz, at which the thickness and spreading angle of the liquid film at the injector exit exhibit strong oscillations. At high forcing frequencies, the dominant frequencies of the oscillations in mass flow rate, film thickness, and spreading angle at the injector exit no longer coincide with the imposed frequencies, indicating attenuation of the oscillations and a shift in spectral dominance during downstream propagation through the liquid film. In contrast, their time-mean values vary weakly with forcing frequencies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers