Practical Metallography

Metallurgical failure investigation of fractured horizontal joint fastening bolts in a bearing casing of a heavy-duty gas turbine engine

M. Giller, B. Fischer, T. Gädicke, E. Cagliyan, A. Neidel

Key points

From the paper's conclusion
  • Eight out of sixteen horizontal joint fasteners M 30 × 82 in the turbine bearing casing of a heavy-duty gas turbine engine were found fractured during a routine inspection.

Abstract

Eight out of sixteen horizontal joint fasteners M 30 × 82 in the turbine bearing casing of a heavy-duty gas turbine engine were found fractured during a routine inspection. Some of the other eight were elongated. The fractured fasteners exhibited marked necking. No material defects were found that could have contributed to the failure. There was no evidence of creep damage. The maximum service temperature of 350 °C appears not to have been exceeded. It was determined that the fractured bolts were overloaded in tension, probably due to casing deformation in engine service.