Analysis and research on the vibration characteristics of the pressure maintaining valve of the deaerator based on structural dynamics
Ran Sang, Jianbo Zhang, Yifei Li, Qingzhi Hou, Yinli Liu
Key points
From the paper's conclusion- The results show that the first 10 natural frequencies under both opening conditions fall within 4.79–21.31 Hz, with the first six not exceeding 10.21 Hz, indicating pronounced low-frequency clustering.
Abstract
The deaerator pressure-maintaining valve is a critical control component in a power plant thermal system, and its operational stability directly affects unit safety and economic performance. To investigate abnormal vibration induced by steam flow and unsteady pressure loading, a three-dimensional finite-element model of the valve was established. After geometric simplification, material-property assignment, and mesh-independence verification, a one-way sequential fluid-structure interaction approach was used to map the unsteady pressure distribution obtained from transient flow simulations onto the wetted structural surfaces. Prestressed modal analyses were performed at valve openings of 14 and 28 %, while harmonic response and transient structural dynamic analyses were conducted at the representative opening of 14 %. The results show that the first 10 natural frequencies under both opening conditions fall within 4.79–21.31 Hz, with the first six not exceeding 10.21 Hz, indicating pronounced low-frequency clustering. The spring assembly and guiding structure exhibit relatively large deformation in most normalized mode shapes, demonstrating high local flexibility and dynamic sensitivity. Harmonic response results indicate that the response amplitudes in the 87.5–100 Hz range are relatively high within the investigated frequency band, with larger deformation concentrated mainly in the spring assembly and guiding structure. Transient analysis further shows that the directional displacement at the valve-stem monitoring point exhibits sustained oscillation under time-varying fluid loading, ranging approximately from −0.2 to 0.2 mm. This suggests that the valve stem and spring load-transfer assembly may experience repeated cyclic loading during long-term operation and therefore face a potential fatigue risk. Accordingly, vibration-mitigation measures, including local flow-passage improvement, stiffness enhancement of critical connections, and appropriate damping configuration, are proposed to improve the valve’s dynamic stability and operational reliability. The findings provide a reference for the vibration-resistant design and abnormal-vibration diagnosis of similar steam control valves.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From cavitating flow to vibroacoustic response in a deflector jet servo valve pilot stage under wide temperature and back pressure conditionsPhysics of Fluids · 2026
- From Damping Ratios to Waveform Characteristics: A Residue-Based Mechanistic Analysis Framework for Hydropower Mechanical VariablesMachines · 2026
- Structural Response and Modal Characteristics of a Francis Turbine Runner: A Numerical InvestigationWater · 2026
- Dynamic characteristics of the head cover of a variable-speed pump-turbineJournal of Physics: Conference Series · 2026
- Research on cracks of stay vanes in a large Francis hydropower unitJournal of Physics: Conference Series · 2026
- Seismic Performance and Reinforcement Strategies for ±600 kV Suspended Converter Valves — Part1: Seismic VulnerabilitiesSAE technical papers on CD-ROM/SAE technical paper series · 2026