Effects of temperature and pH on early degradation of anion exchange membranes
Rosendo Rojas-Barragán, Carlos O. Castillo-Araiza, José S. Mendoza-Figueroa, Guadalupe Ramos-Sánchez
Key points
From the paper's conclusion- These findings demonstrate that degradation processes are activated at early operational stages, requiring precise control of initial operating conditions in electrodialysis systems to limit performance decay.
Abstract
The degradation of anion exchange membranes (AEMs) remains a major limitation to the broader deployment of membrane-based electrochemical devices. Although the operating conditions known to promote membrane deterioration are broadly recognized, the specific operating regimes and timescales that initiate degradation have not been resolved. This uncertainty hinders the definition of operational windows that are required to achieve stable and efficient membrane utilization. This work examines two degradation protocols representative of electrodialysis operating environments: thermal exposure and alkaline exposure, investigated both independently and in combination. In contrast to prior studies centered on extended operation (>2 years), the present analysis targets short exposure intervals (≤1, 24, and 48 h). The impact of these conditions was quantified through measurements of ionic conductivity, ion exchange capacity, electron microscopy, and spectroscopic analyses. Both temperature and alkaline exposure result in a continuous decrease in membrane conductivity through distinct electrochemical responses. Alkaline conditions decrease conductivity and shift the phase angle in Bode analysis toward values approaching zero, consistent with predominantly resistive behavior. In contrast, thermal exposure decreases conductivity while maintaining a nearly constant phase angle, indicating retention of capacitive contributions. These observations indicate that alkaline conditions induce a decrease in the magnitude of double-layer and diffusion boundary layer capacitances, reflected in the shift of the phase angle toward resistive behavior. When combined, elevated pH exerts a greater influence on degradation than temperature alone. Time-resolved measurements revealed a continuous, approximately linear increase in resistivity within the first hour, demonstrating that degradation initiates immediately upon exposure. Scanning electron microscopy (SEM) reveals surface morphological deterioration, while infrared spectroscopy indicates chemical transformation of functional groups. These findings demonstrate that degradation processes are activated at early operational stages, requiring precise control of initial operating conditions in electrodialysis systems to limit performance decay.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Durability assessment of single-cell AEMWE configurations under accelerated stress testingInternational Journal of Hydrogen Energy · 2026
- Degradation of Anion Exchange Membrane Water Electrolyzers Under Shutdown and Open-Circuit Transients: Protocols, Mechanisms, Diagnostics, and MitigationHydrogen · 2026
- Conductivity of Anion-Exchange Membranes with Strongly and Weakly Basic Fixed Groups in Phosphate-Containing SolutionsInternational Journal of Molecular Sciences · 2026
- From Membranes to Catalyst Layers: Molecular and Interfacial Design of Anion-Exchange Polyelectrolytes.Accounts of chemical research · 2026
- Poly(fluorene)-Based Anion Exchange Membranes, Part 1: Effect of Pendant Alkyl Chain Length on Membrane PropertiesMacromolecules · 2025
- Structure−Property Relationship of Dialkyl and Spirocyclic Poly(biphenyl piperidinium)-Based Anion Exchange MembranesChemistry of Materials · 2026