Clinical chemistry and laboratory medicine

A preanalytical quality indicator framework for automated extracellular vesicle separation.

Anna Maria Zimbo, Valentina Crapella, Selena Mimmi, Elisabetta Pingitore, Anna Maria Tolomeo, Khushboo Fatima, Annarita Scardamaglia, Costanza Maria Cristiani,

Neuroscience Research Center, Department of Medical and Surgical Sciences, University Magna Graecia of Catanzaro, Catanzaro, Italy. · Department of Experimental and Clinical Medicine, University Magna Graecia of Catanzaro, Catanzaro, Italy.

Key points

From the paper's conclusion
  • This proof-of-concept framework establishes analytical prerequisites. No single platform optimizes all parameters; selection should be driven by intended application: EXODUS for sensitivity-limited discovery, Summit for analytical standardization, manual SEC for morphological reference. Validation in disease cohorts is required before clinical implementation.

Abstract

OBJECTIVES: Clinical translation of extracellular vesicle (EV)-based diagnostics is constrained by preanalytical variability in separation workflows. We developed a preanalytical quality indicator framework for automated EV separation, anchored to IFCC, EFLM, and MISEV2023 standards. This proof-of-concept study establishes analytical prerequisites; validation in disease cohorts is required before clinical implementation. METHODS: Paired serum and plasma from 10 healthy controls were processed by EXODUS, Summit, and manual SEC. Endpoints included NTA yield, particle-to-protein ratio (PPR), intra-matrix reproducibility (CV%), and tetraspanin preservation (CD9, CD63, CD81) by SP-IRIS. RESULTS: EXODUS achieved the highest particle concentration and PPR, exceeding SEC-based methods by 5- to 10-fold. Summit showed the lowest process variation (CV% <20 %) in serum (18.9 %) and plasma (16.5 %), satisfying IFCC-EFLM robustness criteria. Manual SEC showed the highest variability (serum: 55.3 %; plasma: 45.5 %). SP-IRIS revealed comparable tetraspanin detection across EXODUS and Summit, with qEV showing lower intensity. Summit confirmed superior scalability (4-48 samples/run, 10-15 min hands-on time). CONCLUSIONS: This proof-of-concept framework establishes analytical prerequisites. No single platform optimizes all parameters; selection should be driven by intended application: EXODUS for sensitivity-limited discovery, Summit for analytical standardization, manual SEC for morphological reference. Validation in disease cohorts is required before clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers