Impact of dried blood spot diameter and transit time on analyte concentrations and cut-off classification in routine newborn screening.
Nick Flynn, Sarah Hogg, Stuart J Moat
Biochemical Genetics Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK. · Department of Medical Biochemistry, Immunology & Toxicology, University Hospital Wales, Cardiff, UK.
Key points
From the paper's conclusion- DBS size and transit time affect analyte concentrations and classification against screening CoVs. Pre-analytical quality should be optimised to reduce its impact on NBS result classification.
Abstract
OBJECTIVES: To assess the effect of dried blood spot (DBS) diameter and specimen transit time on newborn screening (NBS) analyte concentrations and classification against cut-off values (CoV) using routine NBS data. METHODS: DBS size and quality were assessed using a validated computer vision algorithm. Ordinary least squares analysis assessed associations between differences in DBS diameter and differences in within-batch duplicate thyroid stimulating hormone (TSH, n=1,101) and immunoreactive trypsinogen (IRT, n=2,581) results, and between specimen transit time and initial TSH (n=175,774), IRT (n=225,602), amino acids and acylcarnitine (n=227,032) results. The impact of pre-analytical factors on classification against CoVs was modelled using routine NBS data (n=256,554). RESULTS: Differences in DBS diameter were positively associated with percentage concentration differences for both TSH (3.03 % per mm, 95 % CI: 1.87-4.19) and IRT (3.05 % per mm, 95 % CI: 1.96-4.15). Methionine and TSH decreased by 3.79 % (95 % CI: 3.67-3.91) and 2.53 % (95 % CI: 2.24-2.82) respectively, per additional day in transit. Methionine instability showed seasonal variation, with greater declines during wetter months. DBS diameter and transit time were estimated to influence classification against CoVs in 636 (95 % CI: 507-843) UK results annually. Reclassification risk increased for DBS specimens outside the recommended diameter range (8-14 mm; IRT risk ratio: 3.7, 95 % CI: 1.8-7.5) and for transit times ≥7 days (methionine risk ratio 48.6, 95 % CI: 16.9-139.8). CONCLUSIONS: DBS size and transit time affect analyte concentrations and classification against screening CoVs. Pre-analytical quality should be optimised to reduce its impact on NBS result classification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Association of Gestational Age, Birth Weight, and Age at Heel Prick with Biomarkers of Newborn Screening in The Netherlands.International journal of neonatal screening · 2026
- Untargeted Metabolomics of Dried Blood Spots for Inherited Metabolic Disorder Classification.Journal of inherited metabolic disease · 2026
- Development and evaluation of dried blood spot quality control materials in newborn screening for inborn errors of metabolism.The Analyst · 2026
- Application of CLIR-Based Post-Analytical Tools to Dutch NBS Data Demonstrates Its Potential Impact on the Performance of CPT1, GA-1, IVA and MSUD Screening in a Disorder-Specific Way.International journal of neonatal screening · 2026
- Detection of individual false-low total bilirubin results in neonates and young infants using the bilirubin-to-icteric index ratio.Clinical biochemistry · 2026
- Does Capillary or Intravenous Collection of Dried Blood Spots Affect the Results of Amino Acid and Acylcarnitine Profile Studied with Tandem Mass Spectrometry?Metabolites · 2026