Semen analysis external quality assessment: a paradigm shift from statistical consensus to biological variation-based analytical quality specifications.
Xiyan Wu, Weina Li
Center for Reproductive Medicine, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China. · Department of Urology (Andrology), Reproductive and Genetic Hospital of CITIC-Xiangya, Changsha, China.
Key points
From the paper's conclusion- We critically evaluate the transition from state-of-the-art to biological variation (BV)-based analytical quality specifications (APS), examine performance differentials between assisted reproductive technology (ART) centres and general clinical laboratories, and assess emerging technologies including AI-assisted morphology assessment and digital EQA platforms.
Abstract
Semen analysis is the primary diagnostic tool for male fertility evaluation, yet its subjective nature introduces substantial interlaboratory variation that compromises result reliability; despite over three decades of external quality assessment (EQA) practice, coefficients of variation (CV) for core semen parameters remain unacceptably high worldwide. Synthesising evidence from 34 years of global EQA programmes, this review documents interlaboratory CVs of 12.7-138.0 %, 17.0-127.0 %, and 7-375 % for concentration, motility, and morphology, and identifies three structural dilemmas: (1) peer self-referencing bias in assigned value determination, (2) disconnection of allowable total error (TEa) from clinical need, (3) a cognitive threshold effect in morphological interpretation. The principal international schemes - CAP (USA), UK NEQAS, NCCL (China), and QUIP (Germany) - diverge markedly in specimen type, assigned value strategy, and acceptance criteria. We critically evaluate the transition from state-of-the-art to biological variation (BV)-based analytical quality specifications (APS), examine performance differentials between assisted reproductive technology (ART) centres and general clinical laboratories, and assess emerging technologies including AI-assisted morphology assessment and digital EQA platforms. The field is undergoing a paradigm shift from statistical peer consensus toward clinically driven BV-based APS, derived from intra-individual (CV1) and inter-individual (CVG) variation of semen parameters; However, AI systems exhibit systematic analytical bias compared with manual microscopy, which stems from training-set composition, annotator subjectivity, and visual fatigue caused by high-throughput workloads. Independent calibration and version-control validation should be completed prior to clinical application. Priority efforts encompass EQA framework harmonisation aligned with WHO Sixth Edition (2021) and ISO 23162:2021, measurement uncertainty incorporation into TEa derivation, prospective AI algorithm validation, split-sample parallel testing, and disaggregation of morphological APS by defect category (head, midpiece, and tail).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Methodological heterogeneity as a confounding variable in reported trends in human sperm parameters: a critical reappraisal.Reproductive biomedicine online · 2026
- Artificial Intelligence in Semen Analysis and Sperm Selection: Opportunities and Challenges.Andrology · 2026
- AI-assisted diagnostics in male infertility: morphological assessment, molecular stratification, and the translational gap between laboratory performance and clinical utilityMiddle East Fertility Society Journal · 2026
- Reassessing Semen Analysis: Clinical Insights Beyond Sperm Count and Motility.Reproductive medicine and biology · 2026
- Patterns of Semen Quality and Use of Sperm DNA Fragmentation Testing in Men Undergoing Fertility Assessment: A Real-World Observational Study.Methods and protocols · 2026
- Deep-learning based model for sperm morphology assessment using the SMD/MSS datasetFuture Science OA · 2025