Stoichiometric calibration of ceruloplasmin activity with copper enables molar quantification and has implications for the estimation of non-ceruloplasmin-bound copper.
Alexandra M Kane, Kurt T K Giuliani, Melanie Coogan, Linda Sanders, Richard G Ruddell, Matthew Burke, Carel J Pretorius, Jacobus P J Ungerer
Department of Chemical Pathology, Pathology Queensland, Queensland Health, Brisbane, QLD, Australia. · Department of Chemical Pathology, New South Wales Health Pathology, New South Wales Health, Newcastle, NSW, Australia.
Key points
From the paper's conclusion- We describe a method to convert Cp ferroxidase activity to molar concentration and demonstrate its application in a large clinical cohort. This approach enables estimation of NCC, although with considerable uncertainty, and establishment of reference intervals using activity-based measurements. Measurement of Cp by enzymatic activity provides a cost-effective and analytically robust alternative to immunoassays, with advantages in specificity.
Abstract
OBJECTIVES: Ceruloplasmin (Cp) and non-ceruloplasmin-bound copper (NCC) are measured when evaluating liver disease and disorders of copper (Cu) metabolism. Cp mass concentration is typically determined by immunoassays that detect both apo- and holoceruloplasmin. In contrast, enzymatic assays measure Cp ferroxidase activity and are therefore specific for holoceruloplasmin. Their clinical use has been limited by the absence of a method to convert enzyme activity to molar Cp concentration and to estimate NCC. METHODS: Cp ferroxidase activity and serum Cu concentrations were measured in a training dataset (n=924) to define their linear relationship and derive a conversion factor based on the stoichiometry of six Cu atoms per Cp molecule. This factor was applied to an independent validation cohort (n=12,635). Cp activity, Cp mass concentration, and serum Cu were compared, and reference intervals for Cp activity and NCC were established. RESULTS: The calibration of Cp activity assay against Cu concentration yielded a conversion factor of 0.0030 for expressing Cp activity in molar units. Reference intervals for Cp activity were 1.5-3.7 μmol/L in males and 1.6-4.3 μmol/L in females. Comparison with nephelometric Cp measurements demonstrated a positive bias and evidence of analytical interference in a subset of samples. CONCLUSIONS: We describe a method to convert Cp ferroxidase activity to molar concentration and demonstrate its application in a large clinical cohort. This approach enables estimation of NCC, although with considerable uncertainty, and establishment of reference intervals using activity-based measurements. Measurement of Cp by enzymatic activity provides a cost-effective and analytically robust alternative to immunoassays, with advantages in specificity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Implementation of an Automated Lipoprotein(a) Assay on a Third-Party Automated Analyzer: Validation, Method Comparison, and Clinical Impact of Formula-Based Mass-to-Molar Conversion.The journal of applied laboratory medicine · 2026
- Association of copper exposure with metabolic syndrome: a dose-response meta-analysis.BMC endocrine disorders · 2026
- Commonly used C‐peptide assays show differing associations with CGM metricsDiabetes Obesity and Metabolism · 2025
- Commutability Assessment of Materials for Serum Copper Measurement Using the IFCC Difference-in-Bias and the CLSI EP30 Approaches.Annals of laboratory medicine · 2026
- Exchangeable copper concentration and 3-kilodalton ultrafiltered urinary copper measurements are successfully adapted and partially validated in dogs.American journal of veterinary research · 2026
- Unveiling the role of abnormal copper metabolism in systemic lupus erythematosus.Journal of autoimmunity · 2026