Could calprotectin and pentraxin 3 be measured in cerebrospinal fluid – a verification study
Helena Čičak, Ana Sruk, Željka Šarčević, Latica Friedrich, Marko Kutleša, Marija Santini, Renata Laškaj, Ivana Zobić,
Key points
From the paper's conclusion- This study aimed to verify the manufacturer’s claims for precision, limit of quantitation (LoQ) and stability for calprotectin using fCAL turbo reagent (Bühlmann Laboratories AG, Schonenbuch, Switzerland); precision and linearity for PTX3 using Human PTX3 ELISA Kit (BioVendor Group, Brno, Czech Republic) in CSF.
Abstract
Objectives Calprotectin and pentraxin 3 (PTX3) have emerged as potential biomarkers of central nervous system inflammatory diseases, yet evidence based analytical verifications in cerebrospinal fluid (CSF) is lacking. This study aimed to verify the manufacturer’s claims for precision, limit of quantitation (LoQ) and stability for calprotectin using fCAL turbo reagent (Bühlmann Laboratories AG, Schonenbuch, Switzerland); precision and linearity for PTX3 using Human PTX3 ELISA Kit (BioVendor Group, Brno, Czech Republic) in CSF. Methods Samples were collected in additive-free tubes and centrifuged at 400 g, 10 min. Calprotectin was measured on Atellica Solution analyser (Siemens), PTX3 was determined by ELISA method on the Thunderbolt analyser (Gold Standards Diagnostics). The verification protocol was carried out according to Clinical and Laboratory Standards Institute (CLSI) guidelines: precision by EP15-A3, LoQ verification by EP17-A2, and linearity by EP6-A. Calprotectin stability at −20 °C for 7 days was assessed in three CSF samples. Results The CV%s for calprotectin precision were 4.52 % and 1.66 %; for PTX3 were 6.0 % and 8.9 %, respectively. The declared LoQ for fCAL turbo of 50.0 μg/L (CV%<20 %) was verified. The stability equation for calprotectin did not exceed the MPD (41.6 %), and it was y=−0.15× (95 % Cl −0.49 to 0.19), indicating stability at −20 °C for 7 days. The method for PTX3 was linear over the manufacturer declared ranges (3,212.0–406.0 and 3,315.0–411.0 ng/L). Conclusions This study showed that Bühlmann fCAL turbo reagent and the Biovendor Human PTX3 ELISA kit support the determination of calprotectin and PTX3 in CSF for research purposes, with potential future clinical applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-162 Cut-off value for ß-trace protein (ß-TP) as a rapid diagnostic of cerebrospinal fluid (CSF) leak detectionClinical Chemistry · 2026
- Stability of serum calprotectin as an emerging inflammatory biomarker: a five-day study at -20 °C and -80 °C using two analytical methods.Laboratory medicine · 2026
- Estimation of biological variability of inflammatory biomarkers EDN, suPAR and plasma calprotectin.Scandinavian journal of clinical and laboratory investigation · 2026
- B-217 Newly developed ELISA for detection of circulating calprotectin in serum and plasmaClinical Chemistry · 2026
- Challenges in measuring serum calprotectin in autoinflammation: a comparative study of different immunoassays.Molecular and cellular pediatrics · 2026
- 56 Closing the Evidence Gap in CSF Total Protein: Lifespan Reference Intervals Derived by Indirect EstimationAmerican Journal of Clinical Pathology · 2026