科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ ERJ open research2026-07-01

Association of PiSlope with lung function decline in individuals with preserved spirometry: a prospective cohort study.

Suyin Huang, Fan Wu, Yuheng Wang, Kunning Zhou, Qi Wan, Gaoying Tang, Zhishan Deng, Fangyan Wu, Cuiqiong Dai, Lifei Lu, Xiaohui Wu, Xiaoyu Wang, Junfeng Lin, Guannan Cai, Xianliang Zeng, Ping Wang, Changli Yang, Shengtang Chen, Yongqing Huang, Shuqing Yu, Yu Deng, Pixin Ran, Yumin Zhou

一句话结论 · In one sentence

Lower PiSlope was associated with faster lung function decline and increased airflow obstruction risk in participants with preserved spirometry, but the association between PiSlope and progression to airflow obstruction was not significant after adjustment.

原始摘要(英文原文)· Original abstract
BACKGROUND: Airway remodelling precedes airflow obstruction in COPD. Pi10 assumes a consistent fixed slope between airway wall thickness and lumen perimeter across individuals. PiSlope comprehensively quantifies airway wall thickening, which is associated with increased acute exacerbation and mortality risk. Whether PiSlope is associated with respiratory prognosis in participants with preserved spirometry is unknown. METHODS: Participants with preserved spirometry with complete baseline questionnaires, spirometry and chest computed tomography were enrolled from a 3-year prospective Early Chronic Obstructive Pulmonary Disease (ECOPD) cohort study and divided into four groups by PiSlope quartile (Q) (Q1: PiSlope ≥0.4946, Q2: 0.4550≤ PiSlope <0.4946, Q3: 0.4149≤ PiSlope <0.4550, Q4: PiSlope <0.4149). Clinical outcomes included lung function decline and risk of airflow obstruction progression. RESULTS: 1140 participants with preserved spirometry were included and 1067 (93.6%) completed at least one follow-up lung function assessment. One standard deviation decrease in PiSlope was associated with accelerated decline in pre-bronchodilator forced expiratory volume in 1 s (FEV1) (adjusted difference 5 mL·year-1, 95% CI 1-9 mL·year-1; p=0.007) and post-bronchodilator FEV1 (adjusted difference 4 mL·year-1, 95% CI 0-9 mL·year-1; p=0.033), and increased airflow obstruction risk (unadjusted: OR 1.21, 95% CI 1.01-1.36, p =0.038; adjusted: OR 1.13, 95% CI 0.87-1.32, p=0.307). Q2-Q4 had accelerated decline in pre-bronchodilator FEV1 and FEV1 % predicted, compared with Q1 (all p<0.05). The third-year risk of airflow obstruction progression was higher in Q2 (adjusted OR 2.40, 95% CI 1.13-5.08; p=0.022), Q3 (adjusted OR 1.71, 95% CI 0.77-3.82; p=0.188) and Q4 (adjusted OR 2.04, 95% CI 0.92-4.53; p=0.078) than in Q1. CONCLUSION: Lower PiSlope was associated with faster lung function decline and increased airflow obstruction risk in participants with preserved spirometry, but the association between PiSlope and progression to airflow obstruction was not significant after adjustment.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Association of PiSlope with lung function decline in individuals with preserved spirometry: a prospective cohort study. — 科研速览 Science Skim