Bicuspidization of a severely dysplastic aortic valve in a neonate.
Ivan Kozyrev, Mathieu Vergnat, Philipp Suchowerskyj, Benjamin Bierbach, Claudia Arenz, Boulos Asfour
Department of Pediatric Cardiac Surgery, University Hospital Bonn, Bonn, Germany · Department of Pediatric Cardiology, University Hospital Bonn, Bonn, Germany
Key points
From the paper's conclusion- This video tutorial demonstrates our technique of bicuspidization of a severely dysplastic neonatal aortic valve by commissural reconstruction, extensive leaflet shaving and limited free-edge remodelling.
Abstract
Severe congenital aortic valve stenosis in neonates remains a challenging lesion requiring individualized treatment. While balloon aortic valvuloplasty and surgical valvotomy are established treatment options, neonates with severely dysplastic valve morphology may benefit from anatomical valve reconstruction in addition to relief of obstruction. This video tutorial demonstrates our technique of bicuspidization of a severely dysplastic neonatal aortic valve by commissural reconstruction, extensive leaflet shaving and limited free-edge remodelling. Our ultimate goal of tricuspid valve repair was impossible in this scenario.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tricuspidization of a unicuspid aortic valve in an adolescent using selective single-cusp replacement.Multimedia manual of cardiothoracic surgery : MMCTS · 2026
- Alfred Kocher technique for prevention of patient-prosthesis mismatch in paediatric patients.Multimedia manual of cardiothoracic surgery : MMCTS · 2026
- Bicuspidization of the Unicuspid Aortic Valve: Neocommissure Reconstruction Preserving the Native Free Margin.Annals of thoracic surgery short reports · 2026
- Immediate and long-term outcomes of aortic commissurotomy for severe congenital aortic valve stenosis in infants: a single-center experience.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
- Primary Treatment of Congenital Aortic Stenosis in Infants: A Comparative Analysis of Balloon Aortic Valvuloplasty and Surgical Aortic Commissurotomy.Journal of the Saudi Heart Association · 2026
- Neonatal Common Atrioventricular Valve Replacement After Failed Staged Biventricular Repair.World journal for pediatric & congenital heart surgery · 2026