Factors associated with radiographic and clinical outcomes after posterior long-segment instrumentation for neurologically intact thoracolumbar fractures: a single-center retrospective study.
Onur Suer, Anıl Murat Ozturk
Department of Orthopaedics and Traumatology, Izmir City Hospital, İzmir-Türkiye. · Department of Orthopaedics and Traumatology, Ege University Faculty of Medicine, İzmir-Türkiye.
Key points
From the paper's conclusion- Posterior long-segment fixation for neurologically intact T11-L2 fractures provided substantial early radiographic correction with generally limited long-term loss of alignment and low final pain levels. Nevertheless, radiographic correction did not necessarily translate into complete functional recovery, as reflected by persistent variability in SF-36 domains. Among the variables analyzed, AO fracture type showed the most consistent association with correction loss and patient-reported outcomes. These hypothesis-generating findings suggest that fracture morphology may be associated with outcomes and may help frame post-operative expectations and follow-up discussions in similar patient populations. However, confirmation in larger, prospective, and comparative studies is required.
Abstract
BACKGROUND: This study aimed to quantify radiographic correction and long-term maintenance, assess pain and health-related quality of life, and identify factors associated with outcomes after standardized posterior long-segment fixation for neurologically intact traumatic thoracolumbar junction fractures. METHODS: This single-center retrospective cohort study included consecutive adults with acute traumatic T11-L2 fractures treated between March 2014 and February 2023 with posterior long-segment pedicle screw instrumentation (two levels above and two levels below, including fracture-level screws) without decompression. Patients required at least 24 months of radiographic follow-up, available pre-operative sagittal computed tomography images, and early post-operative and final lateral radiographs. Imaging parameters were vertebral compression angle (VCA) and anterior/posterior vertebral corpus height. Clinical outcomes were final Visual Analog Scale (VAS) and 36-item short form health survey (SF-36) scores, which were assessed cross-sectionally at final follow-up and therefore reflect final health status rather than change from pre-operative levels. Paired comparisons were used for longitudinal imaging changes, and multivariable linear regression with robust standard errors was used to evaluate factors associated with final outcomes. RESULTS: Seventy-eight patients were included (mean age 40.2±13.9 years; 65.4% male), with a median follow-up of 48 months. VCA changed from 11.75° (7.83-16.48) preoperatively to 4.30° (2.55-6.65) early postoperatively and was 6.00° (4.00-8.80) at final follow-up, indicating limited correction loss over time. Restoration of both anterior and posterior vertebral body heights was observed, with partial loss at final follow-up. Final pain levels were low (VAS 1 [interquartile range=1-1]). In adjusted analyses, AO fracture type was associated with greater VCA loss and poorer SF-36 scores across several domains, particularly for AO type C fractures. However, the number of type C fractures was limited (n=9). Superficial wound infection occurred in 5 patients (6.4%) and resolved with local care and antibiotics; no deep infection, implant failure, revision surgery, or junctional complications were observed. CONCLUSION: Posterior long-segment fixation for neurologically intact T11-L2 fractures provided substantial early radiographic correction with generally limited long-term loss of alignment and low final pain levels. Nevertheless, radiographic correction did not necessarily translate into complete functional recovery, as reflected by persistent variability in SF-36 domains. Among the variables analyzed, AO fracture type showed the most consistent association with correction loss and patient-reported outcomes. These hypothesis-generating findings suggest that fracture morphology may be associated with outcomes and may help frame post-operative expectations and follow-up discussions in similar patient populations. However, confirmation in larger, prospective, and comparative studies is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short-segment fixation including the fractured vertebra versus long-segment fixation in thoracolumbar fractures a ≥10-year comparative study.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2026
- Radiological and functional outcomes of percutaneous short same-segment fixation versus long-segment fixation in traumatic thoracolumbar fractures: a retrospective comparative studyEgyptian Journal of Neurosurgery · 2026
- Application of the pivot forward combined leveraging technique in the treatment of thoracolumbar fractures: a finite element analysis and clinical study.Frontiers in surgery · 2026
- Longitudinal radiographic comparison of percutaneous and open pedicle screw fixation for thoracolumbar burst fractures: A two-year follow-up study.Injury · 2026
- Long-segment posterior spinal instrumentation with intracanal bone fragment compaction for indirect anterior column support: a single-arm feasibility study in high load-sharing classification score thoracolumbar burst fractures.Neurological research · 2026
- Efficacy and Safety of Percutaneous Pedicle Screw Fixation for Neurologically Intact Thoracolumbar Burst Fractures: A Prospective Interventional Study.Cureus · 2026