Finite element analysis of the mechanical behavior of stiffened cold-formed built-up CFST flat columns.
Wenjing Yu, Haijie Wang, Qing Jiang, Hanqin Wang
Anhui Technical College of Water Resources and Hydroelectric Power, Hefei, China. · School of Civil Engineering, Hefei University of Technology, Hefei, China.
Key points
From the paper's conclusion- The results indicate that, compared with the non-stiffened control specimen, the stiffened configuration provides higher axial and cyclic load-bearing capacity, and more effective suppression of local outward bulging.
Abstract
To address insufficient lateral restraint and the susceptibility of the flat walls of traditional concrete-filled steel tubular (CFST) rectangular flat columns, a built-up rectangular CFST flat column with integrated longitudinal cold-formed stiffening ribs is proposed. The FE model was validated against the global response of a welded-plate CFST flat-column specimen. The model was then used to study the axial-compression and quasi-static cyclic behavior of the proposed columns. The coupled effects of aspect ratio, tube thickness, and rib dimensions were evaluated. The individual effects of tube thickness and rib dimensions under axial compression were further examined through the supplementary decoupled analysis. The results indicate that, compared with the non-stiffened control specimen, the stiffened configuration provides higher axial and cyclic load-bearing capacity, and more effective suppression of local outward bulging. Within the investigated parameter range, the coupled increase in tube thickness and rib dimensions improves axial and cyclic performance, while the decoupled analysis indicates that tube thickness is the dominant parameter governing axial load-bearing capacity and rib dimensions mainly contribute to local outward deformation control and post-peak load retention. These findings provide a reference for the parametric design and engineering application of stiffened cold-formed built-up rectangular flat CFST columns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial performance of concrete-encased cold-formed steel composite columns with optimized stiffened sectionsScientific Reports · 2026
- Out-of-Plane Stability Bearing Capacity of Concrete-Fileld Steel Tubular Double-Cross Columns: Calculation Method and Finite Element VerificationBuildings · 2026
- Buckling and Mechanical Behavior of Single Through-Type and Plate-Reinforced X-Shaped Concrete-Filled Steel Tubular ColumnsBuildings · 2026
- Experimental and numerical analysis of square tubed steel-reinforced concrete columns: Confinement mechanism and modelingEngineering Structures · 2025
- Axial compression behavior of hybrid fiber reinforced concrete encased cold‐formed steel composite columns: An experimental and theoretical investigationStructural Concrete · 2026
- Compressive Strength and Stiffness of Steel-Reinforced Concrete Stub Columns Under Axial CompressionBuildings · 2026