Serial ultrasound assessment of flexor carpi ulnaris and biceps brachii cross-sectional area in critically ill patients: A prospective cohort study.
Keiichiro Aoki, Fumihito Kasai, Kazuki Komaba, Jin Saito, Akira Yoshikawa, Naonori Tashiro, Hiroyasu Inoue, Kengo Uchibori,
Department of Occupational Therapy, School of Rehabilitation, Tokyo Professional University of Health Sciences, Koto-ku, Tokyo, Japan. · Department of Rehabilitation Medicine, Showa Medical University, School of Medicine, Shinagawa-ku, Tokyo, Japan.
Key points
From the paper's conclusion- Serial ultrasound documented decreases in FCU and BB CSA in this small cohort, with an exploratory direct comparison identifying a greater proportional FCU decrease on day 7. These findings support further evaluation of FCU ultrasound as an additional muscle-monitoring measure. Its value for earlier detection of muscle wasting or diagnosis of ICU-acquired weakness requires direct validation.
Abstract
BACKGROUND: Serial ultrasound measurements may help characterize muscle wasting in critically ill patients. The flexor carpi ulnaris (FCU) is a superficial forearm muscle that may provide an additional assessment site. We described longitudinal FCU and biceps brachii (BB) cross-sectional area (CSA) changes and explored between-muscle differences and clinical associations. METHODS: This prospective two-center observational study enrolled 23 intensive care unit (ICU) patients; 20 were included in the analysis (median age, 57 years; range, 33-82). CSA was measured on days 0, 5, 7, and 14 after ICU admission. Analyses used Friedman tests, exact conditional Wilcoxon signed-rank tests with Bonferroni correction, and exploratory Spearman correlations. Post hoc between-muscle comparisons assessed participant-level percentage changes. RESULTS: Mean FCU CSA decreased from 1.36 to 1.08 cm² and mean BB CSA from 6.08 to 5.09 cm² over 14 days, corresponding to reductions of 20.9% and 16.4% in the unrounded group means. The median paired difference in percentage change (FCU minus BB) was -11.9 percentage points on day 7 (unadjusted p = 0.0023), meeting the Bonferroni threshold of 0.05/3. Differences on days 5 and 14 did not meet this threshold (p = 0.1429 and p = 0.2024). Baseline CSA values were correlated (ρ = 0.845, p < 0.001), as were 14-day percentage changes (ρ = 0.549, p = 0.0122); correlation p-values were unadjusted. CONCLUSIONS: Serial ultrasound documented decreases in FCU and BB CSA in this small cohort, with an exploratory direct comparison identifying a greater proportional FCU decrease on day 7. These findings support further evaluation of FCU ultrasound as an additional muscle-monitoring measure. Its value for earlier detection of muscle wasting or diagnosis of ICU-acquired weakness requires direct validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasonographic evaluation of quadriceps femoris muscle mass in critically ill patients aged 60 years and older: a prospective observational study.Frontiers in aging · 2026
- ULTRASOUND OF THE THENAR EMINENCE ACCURATELY DETECTS LOSS OF MUSCULAR MASS IN PATIENTS ADMITTED TO A SURGICAL INTENSIVE CARE UNIT.Clinical nutrition ESPEN · 2026
- High versus standard-protein provision and muscle loss in critically ill patients assessed by muscle ultrasound: A prospective ancillary study of a randomised controlled trial.Clinical nutrition (Edinburgh, Scotland) · 2026
- Rethinking Muscle Wasting in Critical Illness: A Systematic Review and Meta-Analysis of Myofiber Size and Protein Turnover.Critical care medicine · 2026
- Comparing bedside and CT-derived muscle mass assessment methodologies at intensive care unit admission: A critical step towards bedside detection of reduced muscle massClinical Nutrition · 2026
- Dynamic changes in quadriceps and diaphragm thickness for early diagnosis of ICU-acquired weakness in elderly ICU patients: a prospective bedside ultrasound study.Frontiers in medicine · 2026