Analysis of porphyrins from serum and the benefit of inert biphenyl columns for liquid chromatography separation.
Moritz Unnerstall, Manfred Fobker, Patrick Christian Opitz, Lukas Helmer, Eric Suero Molina, Simone König
Service Unit Proteomics, Medical Faculty, University of Münster, Münster, Germany. · Clinical Laboratory, University Clinic Münster, Münster, Germany.
Key points
From the paper's conclusion- Here, we demonstrate advantages of the replacement of the C18 with an inert biphenyl (iBP) column, which improved separation resolution and increased detection sensitivity in LC-MS of six porphyrins (uroporphyrin I, hepta-, hexa-, and pentacarboxyporphyrin I, coproporphyrins I and III) associated with the heme biosynthesis pathway.
Abstract
Reversed-phase liquid chromatography (LC) is a major separation technique for porphyrins. We coupled C18-based LC with mass spectrometry (MS) for the detection of protoporphyrin IX (PPIX) in the context of neurosurgery, where it is used as a fluorescence marker for tumor visualisation. Here, we demonstrate advantages of the replacement of the C18 with an inert biphenyl (iBP) column, which improved separation resolution and increased detection sensitivity in LC-MS of six porphyrins (uroporphyrin I, hepta-, hexa-, and pentacarboxyporphyrin I, coproporphyrins I and III) associated with the heme biosynthesis pathway. They are of potential interest as intermediates and side products in our research on 5-aminolevulinic acid-induced fluorescence-guided neurosurgery. Porphyrins consist of conjugated π-systems which interact with aromatic stationary phases such as BP by taking advantage of π-π stacking interactions. Carryover observed with PPIX on endcapped C18 stationary phase was reduced. This improvement was due to the reduction of non-specific adsorption on metallic surfaces from the LC instrument by using inert column hardware combined with the BP stationary phase. Passivation by chemical vapor deposition was shown to reduce non-specific adsorption in the LC system better than methods using mobile phase additives. PEEK tubing in conjunction with the iBP-column provided the best results and shortened run time. Furthermore, we present a Python-based software tool for automated data processing and analyte quantification. This work contributes to our ongoing developments of porphyrin LC-MS in blood and tissue samples from glioma patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sub-3 μm porous graphitic carbon for highly polar metabolomics: orthogonal selectivity and comparison with HILIC and reversed-phase chromatography.Analytical and bioanalytical chemistry · 2026
- Effect of pore size on plate height for 23-mer oligonucleotides separated using fully porous particles and ion-pairing reversed-phase liquid chromatography.Journal of chromatography. A · 2026
- Thiol-Ene Click-Derived Porous-Layer Open-Tubular Column for Online Purification and Multiplex LC-MS/MS Analysis of Neurotransmitters.Analytical chemistry · 2026
- Development and validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify protoporphyrin IX (PPIX) and zinc (II) protoporphyrin IX (Zn-PPIX), in human plasma.Analytical biochemistry · 2026
- Recent Advances in Pharmaceutical and Medical Applications in the Area of Selected Porphyrinoids Connected with PLGA or PLGA-Based ModalitiesPolymers · 2025
- Electrochemical Characterization and Structural Analysis of a Novel Cobalt Phthalocyanine/Histidine-Modified Carbon Paste Biomimetic Composite: Selective Voltammetric Determination of Bisphenol A in Aqueous Media.Biomimetics (Basel, Switzerland) · 2026