Dielectrophoresis and ζ-potential as potential low-cost complements to patch clamp for measurement of cell electrophysiology.
Rashedul Hoque, Fatima H Labeed, Srdjan Cirovic, Michael Pycraft Hughes
Centre for Biomedical Engineering, University of Surrey, Guildford, United Kingdom. · Department of Biology, United Arab Emirates University, Al Ain, United Arab Emirates.
Key points
From the paper's conclusion- In this paper we use DEP and ELS to examine the electrophysiology of human bladder carcinoma cell line HTB-9 following treatment with ATP, glibenclamide and tetraethylammonium, and compare the results to published data obtained by patch clamp.
Abstract
Cell electrophysiology is a useful measure of cell function, including ionic state and channel activity, and the way these are altered by pharmacological intervention. However, measurement of whole-cell electrical properties such as resting membrane potential Vm and membrane whole-cell capacitance and conductance is difficult, which has limited the more widespread adoption of electrophysiology in cell biology and drug discovery. The gold-standard method for acquiring this data is patch clamp, a method of measuring single cells that uses a micromanipulated micropipette in contact with the cell surface. Measurement is difficult, slow, and requires a highly skilled operator, whilst automated alternatives are expensive to run. Other methods such as flow cytometry are unable to provide absolute values of Vm, or measure conductance and capacitance characteristics. Dielectrophoresis (DEP) and electrophoretic light scattering (ELS) have recently been shown to provide useful methods of directly measuring absolute Vm and other parameters, whilst examining many more cells (typically tens of thousands in under a minute). In this paper we use DEP and ELS to examine the electrophysiology of human bladder carcinoma cell line HTB-9 following treatment with ATP, glibenclamide and tetraethylammonium, and compare the results to published data obtained by patch clamp. Results indicate that DEP yields Vm and membrane conductance values that are highly comparable to data from patch clamp, at high speed and low cost, demonstrating the usefulness of techniques such as DEP and ELS for electrophysiological study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dielectrophoretic estimation of resting membrane potential in excitable cells.PloS one · 2026
- ProDEP: a programmable CMOS dielectrophoresis platform for standardized cell manipulation and effective DEP phenotyping.Analytical methods : advancing methods and applications · 2026
- Unraveling the dielectric heterogeneity response of cell lines under electroporation: a microfluidic single-cell on-chip system.Microsystems & nanoengineering · 2026
- Electrical Signatures of Life: A Review of Cell Electrophysiology and Dielectric Analysis (2015-2026).Electrophoresis · 2026
- Selective dielectrophoretic array formation of unmodified B cells through microparticle modification of non-target cells.Analytical methods : advancing methods and applications · 2026
- Dielectric polarization phenomena in microalgae under a pulsed electric fieldJournal of Applied Physics · 2026