Key points
From the paper's conclusion- Assessing pointing acuity using LMC with a standardized test protocol has an acceptable concurrent validity when compared to a 3D-based multi camera system (QMC), supporting its potential use in clinical settings.
Abstract
Sensorimotor control of the arm and hand can be disturbed in various health conditions causing deviant and unfavourable movement patterns. This study aimed to evaluate a new clinical test protocol for pointing acuity using the Leap Motion Controller (LMC) and assess the concurrent validity against a standard laboratory motion capture system (Qualisys Motion Capture, QMC). Twenty participants (mean age 44.4 years) performed the pointing acuity tests with eyes open and closed, and with left and right hand. Outcome measure was the mean absolute error (AE) in millimeters (mm) of 10 trials. Pearson's r or Spearman's rho were used to analyse the correlations between LMC and QMC, and Bland-Altman were used to analyse the agreement. There were moderate to very strong correlations (r: 0.67 to 0.95) between LMC and QMC in tests with eyes closed. In contrast, tests with eyes open showed weak correlations; rho 0.27 for both left and right hand. Bland-Altman showed median bias of ≤ 1.4 mm (LoA 0.1 to 17.5 mm) between LMC and QMC with eyes open, and ≤ 5.1 mm (LoA -31.6 to 21.5 mm) with eyes closed. Assessing pointing acuity using LMC with a standardized test protocol has an acceptable concurrent validity when compared to a 3D-based multi camera system (QMC), supporting its potential use in clinical settings. Future research should evaluate its psychometric properties regarding discriminative validity, reliability and responsiveness in various populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concurrent Validity and Agreement of Viewpoint-Dependent Markerless Motion Tracking in Upper-Limb Assessment: A Validation Against Optoelectronic Motion Capture.Sensors (Basel, Switzerland) · 2026
- PinPointer: An offline error measurement system for motor behavior research.Behavior research methods · 2026
- Measurement Uncertainty and Traceability in Upper Limb Rehabilitation Robotics: A Metrology-Oriented ReviewJournal of Sensor and Actuator Networks · 2026
- Criterion Validity of Wrist-Worn IMU-Derived Smoothness Metrics During Functional Upper-Limb Tasks.Bioengineering (Basel, Switzerland) · 2026
- Evaluation of markerless hand-tracking accuracy in VR application designed for hand range-of-motion measurement and rehabilitationJournal of NeuroEngineering and Rehabilitation · 2026
- Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy.Sensors (Basel, Switzerland) · 2026