Diagnostic agreement between Rhinoswabs and joint nose and throat swabs for the detection of influenza and SARS-CoV-2 among symptomatic ambulatory patients in Hong Kong.
Caitriona Murphy, Samuel M S Cheng, Loretta Mak, Hau Chi So, Dennis K M Ip, Malik Peiris, Benjamin J Cowling
World Health Organization Collaborating Centre for Infectious Disease Epidemiology and Control, School of Public Health, The University of Hong Kong, Hong Kong Special Administrative Region, China.
Key points
From the paper's conclusion- Rhinoswabs achieved high agreement with joint NTS for RT-qPCR detection of influenza and SARS-CoV-2. Given their minimal invasiveness Rhinoswabs are a viable alternative specimen type for supervised respiratory virus testing.
Abstract
BACKGROUND: Accurate detection of respiratory viruses relies on appropriate sample collection, but whether joint nose and throat sampling is necessary for high diagnostic performance or whether nose sampling alone can provide comparable results remains uncertain. OBJECTIVES: We evaluated the diagnostic agreement between joint nose and throat swabs (NTS) and Rhinoswab (RhinoMed, Cremorne, Australia), a novel anterior nasal swab for RT-qPCR detection of respiratory viruses among symptomatic outpatients. STUDY DESIGN: Outpatients with febrile acute respiratory illness were enrolled at a clinic in Hong Kong and paired joint NTS and Rhinoswab samples were tested by reverse transcription polymerase chain reaction (RT-qPCR) for influenza A, influenza B, SARS-CoV-2 and human ribonuclease P (RNase P) as an internal control. Diagnostic agreement and RT-qPCR Ct values were compared between the paired samples. RESULTS: Between May 2023 and April 2024, 488 participants provided paired samples. Overall concordance between Rhinoswab and NTS was 98.0% (95% CI: 96.3% to 99.0%) for influenza A, 99.0% (95% CI: 97.6% to 99.7%) for influenza B, and 99.0% (95% CI: 97.6% to 99.7%) for SARS-CoV-2. Cohen's kappa also indicated high agreement for all viruses: 0.95 (95% CI: 0.92 to 0.98) for influenza A, 0.94 (95% CI: 0.88 to 0.99) for influenza B, and 0.92 (95% CI: 0.85 to 0.99) for SARS-CoV-2. Ct values from Rhinoswab were moderately correlated with NTS for all three viruses and RNase P. The majority of discordant samples had Ct values of 30 and above (16/18, 88.9%). CONCLUSIONS: Rhinoswabs achieved high agreement with joint NTS for RT-qPCR detection of influenza and SARS-CoV-2. Given their minimal invasiveness Rhinoswabs are a viable alternative specimen type for supervised respiratory virus testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance of an antigen test for detection of SARS-CoV-2, influenza, and respiratory syncytial virus—a prospective studyClinical Microbiology and Infection · 2026
- Clinical Validation and Diagnostic Performance of a Multiplex Real-Time RT-PCR Assay for the Detection of SARS-CoV-2 and Influenza A Virus in Clinical Specimens Collected in Kazakhstan in 2021 and 2026Microorganisms · 2026
- Comparative evaluation of the GeneSoC FluA/B Detection Kit for influenza A and B virus detection using archived nasopharyngeal specimens.Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy · 2026
- A-380 Comparative Analytical Evaluation of Point-of-Care and Centralized Respiratory Assays For Detection of SARS-CoV-2, Influenza, and RSVClinical Chemistry · 2026
- Impact of case definition on respiratory virus surveillance: findings of a 12-year prospective studyEuropean Journal of Public Health · 2026
- Performance of a Rapid Triple Test, SARS-CoV-2 + Influenza A/B + Respiratory Syncytial Virus Compared With RT-PCR for Ambulatory Pediatric PatientsThe Pediatric Infectious Disease Journal · 2025