A national survey on laboratory practices for specimen processing, streptococcus pneumoniae identification and antimicrobial susceptibility testing in CARSS Hospitals in China.
Cui Jian, Xueman Wang, Shaozhen Yan, Chao Xu
Department of Laboratoty Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Key points
From the paper's conclusion- Only 49.65% used ATCC 49619 for QC.Significant variations exist in laboratory practices for respiratory specimen processing and S. pneumoniae workup across CARSS hospitals.
Abstract
Standardized processing of respiratory specimens and accurate identification and antimicrobial susceptibility testing (AST) of Streptococcus pneumoniae are crucial for clinical management. This study investigated laboratory practices for specimen processing, S. pneumoniae identification, and AST of S. pneumoniaeamong CARSS hospitals. A nationwide online survey was conducted in 2023. After data cleaning, 3,297 valid questionnaires were analyzed. The survey assessed specimen distribution, sputum/BALF processing, identification and quality control (QC). Sputum was the most common specimen(39.92%), followed by "others" (20.83%), blood (20.47%), urine (14.16%), and BALF (4.58%). Most laboratories performed routine Gram staining on sputum (71.55%) and BALF (66.88%). For sputum smears, 75.80% ~ 86.29% reported semi-quantitative cell/pathogen counts. The dominant acceptability criterion for sputum was > 25 WBCs/LPF and <10 SECs/LPF (98.88%). For unacceptable sputum specimens yielding S. pneumoniae 45.12% laboratories laboratories performed identification/AST only if the bacterial quantity was ≥ 2 + . Common identification methods were Optochin/bile solubility test (53.32%), Vitek GP card (42.74%) and MALDI-TOF MS (30.15%). AST methods included Vitek GP68 (38.76%), disk diffusion (32.91%), gradient diffusion (22.78%) and DL-96STREP cards (21.20%). Notably, 44.10% perform no routine AST QC and 44.62% lacked QC strain ATCC 49619. Only 49.65% used ATCC 49619 for QC.Significant variations exist in laboratory practices for respiratory specimen processing and S. pneumoniae workup across CARSS hospitals. While conventional methods remain prevalent, MALDI-TOF MS adoption is growing.The high proportion of laboratories lacking routine AST QC underscores the need for standardized protocols and enhanced quality assurance nationwide.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving diagnostic stewardship of Streptococcus pneumoniae urine antigen testing among cancer patients.Antimicrobial stewardship & healthcare epidemiology : ASHE · 2026
- A-095 Prevalence, Antimicrobial Resistance and Serotype Distribution of Streptococcus pneumoniae Isolated from Blood Cultures in BrazilClinical Chemistry · 2026
- Pneumococcal serotype distribution and diagnostic yield of serotype-specific urinary antigen detection in adults with CAP in Switzerland, 2016-2021: a prospective cohort study.BMC infectious diseases · 2026
- Bacteriological Spectrum and Antibiotic Utilization in Community-Acquired Pneumonia: An Observational Study at a Tertiary Care Center in Western Uttar Pradesh, India.Cureus · 2026
- Interpretability of Paired Pneumococcal Serotype-Specific IgG Testing in Adults With Solid Tumors: A Retrospective Chart-Review Cohort Study.Cureus · 2026
- Quality of antimicrobial prescribing in non-surgical inpatients: an AQUA-based multicenter cross-sectional study in ChinaFrontiers in Public Health · 2026