PloS one

Orbital computed tomography biomarkers for the assessment of activity of Thyroid Eye Disease.

Bo Sook Han, Min Seok Seo, Eun Soo Kim, Ye-Seul Song, Min Joung Lee

Department of Ophthalmology, Seoul National University Hospital, Seoul, South Korea. · Department of Ophthalmology, Hallym University Sacred Heart Hospital, Anyang, South Korea.

Observational · n=100

Key points

From the paper's conclusion
  • Orbital CT revealed significant differences in EOM volume and intraorbital fat density between patients with active and inactive TED. These findings suggest that quantitative CT analysis may be useful for assessing TED activity.

Abstract

OBJECTIVES: To investigate the relationship between orbital metrics obtained using computed tomography (CT) imaging and inflammatory activity in thyroid eye disease (TED). METHODS: This retrospective study analyzed the medical records and CT images of 85 patients with TED and 15 controls. Orbital segmentation was performed using commercially available software. The volumes and densities of the extraocular muscles (EOMs), intraorbital fat, and lacrimal gland were measured. CT parameters were compared among the control, active TED, and inactive TED groups. Patients were further classified into two subgroups based on disease severity: mild TED and moderate to severe TED, and CT parameters were compared in each severity subgroup. RESULTS: Patients with active TED showed significantly higher thyroid-stimulating immunoglobulin levels than patients with inactive TED (p < 0.001). Orbital CT analysis revealed that the EOM volume was significantly larger in the active TED than in the inactive TED and control groups (p < 0.001). Additionally, intraorbital fat density was higher in patients with active TED (p < 0.001), whereas intraorbital fat volume and EOM density showed no significant differences between the groups. Lacrimal gland parameters did not differ significantly between the groups. Subgroup analysis based on TED severity also indicated that EOM volumes were larger and intraorbital fat densities were higher in the active TED than in the inactive TED (all p < 0.05). CONCLUSIONS: Orbital CT revealed significant differences in EOM volume and intraorbital fat density between patients with active and inactive TED. These findings suggest that quantitative CT analysis may be useful for assessing TED activity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers