Integrated optimization of electroplating wastewater treatment: A comparative assessment of physicochemical treatment configurations and process enhancement using response surface methodology.
Soumaya Ibrahimi, Aicha Gasmi, Karim Kriaa, Farid Fadhillah, Majeed Ali Habeeb, Djamel Ghernaout, Noureddine Elboughdiri, Ahmed Hannachi
Department of Chemical Engineering, Laboratory of Engineering Processes and Industrial Systems, National School of Engineering of Gabes, University of Gabes, Gabes, Tunisia. · College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, Saudi Arabia.
Key points
From the paper's conclusion- The integrated approach shows that variability- responsive optimization enhances treatment efficacy, operational stability, and economic efficiency.
Abstract
This study assesses physicochemical treatment methods for industrial electroplating wastewater (EPW). Monitoring at a full-scale Tunisian facility revealed considerable instability in conventional systems. Residual nickel concentrations ranged from 0.02 ± 0.01 to 60 ± 0.4 mg/L. Chloride levels consistently exceeded regulatory thresholds, ranging from 442 ± 9-1418 ± 10 mg/L. Over 24 weeks, three treatment configurations were evaluated: ferric chloride-based coagulation (Configuration 1), polyaluminum chloride coagulation (Configuration 2), and lime slurry-based chemical attack (Configuration 3). Configuration 3 showed the most consistent performance. It achieved 99% chromium removal, 97% nickel removal, and 50% chloride reduction, while reducing chemical operating costs by 69% (0. 134 €· m ³ compared to 0. 432 €·m-3). A novel optimization strategy is presented that explicitly incorporates variability in influent nickel concentration ([Ni]ᵢ, 33-92 mg/L) as an independent factor. This is applied within a Response Surface Methodology-Central Composite Design, alongside pH (6.3-9.7) and flocculant dosage (2.2-9.4 mg/L). Fluctuations in wastewater composition are treated as a controlled design variable rather than experimental noise. This approach produces a robust predictive model ([Ni]f = f([Ni]ᵢ, pH, [A-PAM]) with high accuracy (R² = 0.9917). The resulting equation enables real- time adaptive chemical dosing. Operators can calculate optimal pH and flocculant requirements based on measured influent concentrations. Statistical analysis identified significant pH-metal loading interactions (F = 5.70, p = 0.044). This confirms that optimal parameters systematically shift with influent composition. Under model-predicted conditions, residual nickel consistently remained below 2 mg/L, despite substantial influent variability. This ensures regulatory compliance. The integrated approach shows that variability- responsive optimization enhances treatment efficacy, operational stability, and economic efficiency.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of Coagulation–Flocculation Conditions for Surimi Processing Wastewater Treatment Using Response Surface MethodologyIOP Conference Series: Earth and Environmental Science · 2026
- Hydrodynamic and electrode optimization of a continuous-flow electrocoagulation reactor for laundry wastewaterDesalination and Water Treatment · 2026
- Dynamic Modeling of Acid Pickling for Sustainable Operation in ElectroplatingIndustrial & Engineering Chemistry Research · 2026
- Development of a cost-effective bipolar electrocoagulation system for enhanced hexavalent chromium removal: empirical modeling and statistical optimizationDiscover Applied Sciences · 2025
- Optimized electrocoagulation with stacked aluminum disc electrodes for ammonia removal from wastewaterResults in Engineering · 2025
- Electrocoagulation of Ketoprofen From Pharmaceutical Wastewater Using Recycled Aluminum 3D Electrodes: Optimization, Kinetic Modeling, and Cost AnalysisChemistrySelect · 2026