Key points
From the paper's conclusion- We evaluated an AI-assisted negative-screening workflow for diabetic retinopathy (DR), retinal vein occlusion (RVO), and age-related macular degeneration (AMD) using 6,904 color fundus photographs independently graded by three retina specialists.
Abstract
The clinical value of artificial intelligence (AI) in fundus photography depends on workflow efficiency as well as diagnostic performance. We evaluated an AI-assisted negative-screening workflow for diabetic retinopathy (DR), retinal vein occlusion (RVO), and age-related macular degeneration (AMD) using 6,904 color fundus photographs independently graded by three retina specialists. In this workflow, AI-negative images were classified as negative without ophthalmologist review, whereas AI-positive images were referred for human interpretation. For each reader-disease pair, the reference standard was agreement between the other two readers; discordant cases were excluded (DR, 1.2%-2.3%; RVO, 0.3%-0.6%; AMD, 6.1%-11.6%). The workflow reduced direct ophthalmologist review to 7.3%-8.0% of images for DR, 11.7%-11.9% for RVO, and 13.5%-16.8% for AMD. For DR, sensitivity decreased significantly (0.9168 to 0.8838; difference, -0.0330; 95% confidence interval [CI], -0.0495 to -0.0165; p < 0.001), whereas specificity did not change significantly (0.9961 to 0.9983; p = 0.183). For RVO, sensitivity was unchanged (0.9807) and specificity did not change significantly (0.9985 to 0.9988; p = 0.320). For AMD, sensitivity decreased significantly (0.8570 to 0.8445; difference, -0.0124; 95% CI, -0.0215 to -0.0033; p = 0.008), whereas specificity did not change significantly (0.9685 to 0.9843; p = 0.324). In an exploratory image-level analysis for at least one target disease, review decreased to 27.7%-30.1%; sensitivity changed from 0.9122 to 0.9039 (difference, -0.0083; 95% CI, -0.0131 to -0.0035; p < 0.001) and specificity from 0.9659 to 0.9804 (p = 0.334). AI-assisted negative-screening can reduce ophthalmologist workload across multiple retinal diseases, but with disease-specific safety trade-offs: because AI-negative images are not reviewed, reduced sensitivity for DR and AMD means a small proportion of true-positive cases would go undetected, potentially delaying diagnosis and treatment for sight-threatening disease. These results support disease-specific implementation strategies that balance workload reduction against missed positive cases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating Artificial Intelligence as a First-Pass Reader in Fundus Photograph Screening: A Multireader Workflow Validation Study.Diagnostics (Basel, Switzerland) · 2026
- AI-Assisted Triage for Diabetic Retinopathy Integrated into Routine Diabetes Care: A Real-World Diagnostic Accuracy Study of the DAIRET® Algorithm.Diagnostics (Basel, Switzerland) · 2026
- Comparison of Retinopathy Screening Performed Using Conventional Methods and an Artificial Intelligence-Assisted System in Prediabetic and Diabetic Patients: A Single-Center Prospective Analysis.Medicina (Kaunas, Lithuania) · 2026
- Artificial Intelligence for Clinical Decision-Making in Retinal Disorders: From Screening and Diagnosis to Treatment and Longitudinal Management.Progress in retinal and eye research · 2026
- Artificial intelligence in diabetic retinopathy: from automated screening to risk-stratified care.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Diabetic Retinopathy Screening Among Federally Qualified Health Center Patients Using Point-of-Care AIJAMA Network Open · 2025