Optics letters

Structured-illumination phase-derivative method for sub-diffraction-limit defect inspection.

Jiating An, Lingbao Kong, Min Xu

Key points

From the paper's conclusion
  • We present a structured-illumination phase-derivative (SIPD) method that is sensitive to phase and identifies defects through the symmetry breaking induced in the reconstructed phase signal.

Abstract

Optical defect inspection is fundamentally constrained by diffraction and by the weak response of intensity-based methods to defects that perturb the optical phase rather than the amplitude of the reflected field. We present a structured-illumination phase-derivative (SIPD) method that is sensitive to phase and identifies defects through the symmetry breaking induced in the reconstructed phase signal. Coherent fringe illumination shifts high-spatial-frequency defect information into the optical passband, and Fourier analysis of a phase-shifting sequence yields a complex field whose phase equals the difference between the two asymmetrically filtered channels. This phase difference varies slowly and smoothly across defect-free regions, whereas a localized defect introduces a sharp anomaly that is selectively enhanced by successive phase derivatives. Using a 0.4 NA objective at 532 nm, we localize defects as small as 100 nm, well below the Rayleigh limit, with a signal-to-noise ratio higher than that of conventional bright-field illumination. The method provides a practical, high-sensitivity route for defect detection and quality control.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Structured-illumination phase-derivative method for sub-diffraction-limit defect inspection — Science Skim