From the paper's conclusion- We report the first, to the best of our knowledge, 100 MHz stretched-pulse mode-locked (SPML) wavelength-swept laser light source and optical coherence tomography (OCT) system.
Abstract
We report the first, to the best of our knowledge, 100 MHz stretched-pulse mode-locked (SPML) wavelength-swept laser light source and optical coherence tomography (OCT) system. The all-polarization-maintaining fiber SPML laser employs a chirped fiber Bragg grating (CFBG) with a linear-in-wavenumber intra-cavity group delay of 93 ps/nm over the 1240 - 1340 nm wavelength range, enabling a 100 nm wavelength sweep within 9.3 ns. The resulting OCT system operates at a 100 MHz A-line rate with a measured axial resolution of 13.5 µm, 90 dB sensitivity, and a 6 dB coherence length of 500 µm. To fully exploit this ultrahigh A-line rate for practical applications, a polygon-mirror-based fast-axis beam scanner is combined with a calibration-based framework that compensates polygon-scanner-induced image artifacts. System performance is demonstrated through large-field, high-speed imaging of a resolution target and high-throughput three-dimensional (3D) inspection of industrial samples, including subsurface imaging of a microSD card and quantitative conformal coating thickness mapping on printed circuit boards.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-sensitivity line-field spectral-domain OCT driven by a power-scaled gain-managed nonlinear fiber source.Optics express · 2026
- Megahertz-rate down-sampled optical coherence tomography based on high-speed k -linear swept laser and deep learningOptics Letters · 2026
- Broadband 2-µm fiber-laser supercontinuum for high-resolution optical coherence tomography.Biomedical optics express · 2026
- Real-time robotically assisted optical coherence tomography with low-latency surface tracking for large-area skin imagingCurrent Directions in Biomedical Engineering · 2026
- Fiber-based electro-optic dual-comb light source for fast linear and nonlinear spectroscopyarXiv · 2026
- Imaging biological tissue at extended depth using swept-source visible-light OCT.bioRxiv : the preprint server for biology · 2026