Four-scanner virtual-conjugation for large field-of-view, broadband one-, two- and three-photon microscopy.
Yufeng Gao, Kangzheng Liu, Jia Yu, Ting Wu, Lina Liu, Jiuling Liao, Hui Li, Bo Wang,
Research Center for Biomedical Optics and Molecular Imaging, Shenzhen Key Laboratory for Molecular Imaging, Guangdong Provincial Key Laboratory of Biomedical Optical Imaging Technology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China. · School of Physics and Optoelectronic Engineering, Guangdong University of Technology, Guangzhou 510006, China.
Key points
From the paper's conclusion- Here, we present a four-scanner virtual-conjugation (4-SVC) system that achieves virtual conjugation on both scanning axes using an all-reflective design.
Abstract
Laser scanning microscopy (LSM) has become an indispensable tool in biomedical research; yet its imaging performance-particularly field-of-view (FOV), resolution, and spectral versatility-is governed by the scanning system. Conventional scanning systems rely on reflective or refractive relay optics to couple the scanning beam into the objective, which inevitably introduces off-axis aberrations or chromatic dispersion, thereby limiting both the accessible FOV and the usable wavelength range. Here, we present a four-scanner virtual-conjugation (4-SVC) system that achieves virtual conjugation on both scanning axes using an all-reflective design. The system exhibits negligible off-axis aberrations at scan angles up to ±11.70° (experiments were performed at ±6.38°) for a 20-mm-diameter beam and delivers >80% transmittance from the visible to the near-infrared region, with minimal chromatic aberration and dispersion. Using the 4-SVC, we demonstrate, for the first time to the best of our knowledge, a one-, two-, and three-photon LSM that achieves a 4-mm FOV with near-submicron resolution over an excitation range of 405-1550 nm. This system enables in vivo imaging of neuronal structures and microglial dynamics across both hemispheres, and discrimination of multiple tissue components in mouse kidney slices via broadband excitation. The 4-SVC eliminates the need for refractive relay optics, offering a versatile scanning solution for applications that simultaneously demand large FOV, high resolution, and broadband spectral compatibility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-scale and dual-channel oblique plane microscopy for multi-resolution imaging of large tissue specimensBiomedical Optics Express · 2026
- Light-Sheet Microscopy beyond 3D Imaging: Scalable and Quantitative Measurement across Biomedical and Analytical SciencesChemical & Biomedical Imaging · 2026
- Programmable illumination and spatially varying aberration correction in a laser scanning confocal microscopy systemJournal of Optics · 2026
- Isotropic, aberration-corrected light sheet microscopy for rapid high-resolution imaging of cleared tissueNature Biotechnology · 2025
- Space-time light-sheet microscopy.Nature communications · 2026
- Multi-immersion oblique plane microscope (miOPM): a reconfigurable platform for high-resolution light-sheet fluorescence microscopy.Nature methods · 2026