Optics express

Low-latency axial depth estimation of 2.82 ms using light field microscopy.

Jiaqi Li, Yu Cao, Hiromasa Oku

Graduate School of Science and Technology, Gunma University, Gunma 3710044, Japan. · Faculty of Informatics, Gunma University, Gunma 3710044, Japan.

Key points

From the paper's conclusion
  • Low-latency axial depth estimation is important for automated microscopic observation and feedback control because estimation delay degrades feedback-control performance and prolongs defocus, thereby reducing the quality of microscopic observation.

Abstract

Low-latency axial depth estimation is important for automated microscopic observation and feedback control because estimation delay degrades feedback-control performance and prolongs defocus, thereby reducing the quality of microscopic observation. This paper presents a low-latency axial position estimation method based on light field microscopy for rapid optimal focal plane determination. A CPU-GPU implementation achieved a measured end-to-end estimation latency of 2.82 ± 0.58  ms across 100 trials. An additional experiment quantitatively validated x-direction displacement estimation using a fluorescent microsphere aggregate, and high-speed closed-loop autofocus was demonstrated using a USAF target and fluorescent microspheres.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers