Facility-specific assessment of indoor airflow stability for repeatable interferometric testing of large optics.
Ji Yong Joo, Jae Woo Lee, Jun Ho Lee, Sang-Won Park, Ho-Soon Yang, Timothy Butterley
Key points
From the paper's conclusion- We simultaneously measured the INTENSE-based effective Fried parameter (r0) and interferometric root-mean-square wavefront error (RMS WFE) of a 1 m-class mirror under four airflow conditions involving forced airflow, local mixing, and no fan operation.
Abstract
Indoor airflow is a major source of uncertainty in interferometric testing of large optics, yet quantitative criteria for identifying conditions that support repeatable measurements remain limited. We simultaneously measured the INTENSE-based effective Fried parameter (r0) and interferometric root-mean-square wavefront error (RMS WFE) of a 1 m-class mirror under four airflow conditions involving forced airflow, local mixing, and no fan operation. For each condition, the primary analysis used ten 1-min measurements, with five additional 1-min measurements used for reproducibility assessment. Session-mean effective r0 alone did not consistently indicate repeatability: the condition with the largest mean effective r0 differed between sessions, whereas the combined forced-airflow and local-mixing condition exhibited the smallest observed repeat-measurement fluctuations in both effective r0 and RMS WFE. Normalized effective-r0 fluctuation was used as a scale-adjusted descriptor for intersession comparison, whereas absolute fluctuation showed a stronger exploratory association with RMS WFE fluctuation. Analyses of low-order Zernike modes and temporal power spectral density provided complementary modal and spectral information. Within the present facility and sampled time scales, these results suggest that the fluctuation of effective r0 may complement its mean value and the corresponding RMS WFE statistics when evaluating measurement repeatability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermally driven indoor air turbulence in a large-scale optical metrology environment: quantitative characterization with an INTENSE system.Optics express · 2026
- Direct density measurements from intersectional FLDIOptics Letters · 2026
- A review of error analysis and compensation methods in white-light interferometric surface topography measurementFrontiers in Physics · 2026
- Development and validation of a pneumatic metrology mount for spaceborne mirrors.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Spatially resolved diagnosis of aero-optical transmission effects in enclosed high-temperature imaging via segmented ray tracing.Optics express · 2026
- Spatiotemporal characteristics of aero-optical effects in the supersonic mixing layerPhysics of Fluids · 2026