Time-of-flight-based waveform measurement technique.
Lijuan Xiang, Xuan Chen, Zhiying Deng, Qiuyan Luo, Zhuoming Du, Houzhi Cai
Key Laboratory of Optoelectronic Devices and Systems of Education and Guangdong Province, Shenzhen Key Laboratory of Photonics and Biophotonics, Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.
Key points
From the paper's conclusion- The relationship between the time-of-flight (TOF) of photoelectrons in the drift tube and their energy was investigated, and an ultrafast pulse waveform measurement technique based on the TOF was presented.
Abstract
A time-dilation imaging camera with a temporal resolution of 5 ps was developed by integrating a 16 times dilation of the incoming optical signal and an 80 ps time-resolved microchannel plate (MCP)- gated detector. Temporal dilation was achieved by the photoelectron energy gradually decreasing over time and a 55 cm sufficiently long drift region. The relationship between the time-of-flight (TOF) of photoelectrons in the drift tube and their energy was investigated, and an ultrafast pulse waveform measurement technique based on the TOF was presented. The dilation pulse voltage is obtained using the TOF, and its slope is derived from the temporal resolution. The dilation pulse waveform was reconstructed using the electron energy and the measuring camera's temporal resolution, while the optical signal was synchronized to 20 different positions along the rising edge of the dilation pulse. The waveform measured by the time dilation imaging camera was consistent with that of the high-speed oscilloscope, with a discrepancy of less than 10%. The 5 ps temporal resolution corresponds to a reciprocal-time equivalent bandwidth of approximately 200 GHz. Within the low-space-charge regime, further optimization of the dilation pulse may provide a route toward higher temporal resolution and equivalent bandwidth.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial swept performance assessment of the BHx streak tube (invited).The Review of scientific instruments · 2026
- White-cell multipass optical parametric amplifier with 91.9% quantum efficiency at 1490 nm.Optics letters · 2026
- Improved Linearity in Short-Pulse Indirect Time-of-Flight Image Sensors Using Dual-Phase Short-Pulse ModulationSensors · 2026
- Accuracy-enhanced ultra-wideband optoelectronic frequency response measurement via residual carrier de-embedding and sideband power correction.Optics letters · 2026
- Fast Pump-Probe Microscopy Imaging with Asynchronous Optical Sampling.The journal of physical chemistry. A · 2026
- Dual-comb time-of-flight measurement via attosecond-resolved active pulse tracking.Optics express · 2026