From the paper's conclusion- We report a compact reflection-type fiber Michelson interferometer with an end-face polyvinyl alcohol (PVA) film, in which a cascaded no-core fiber (NCF)/polarization-maintaining photonic-crystal fiber (PM-PCF) structure provides a feature-rich interference spectrum, while humidity-induced swelling and refractive-index changes of the PVA film produce measurable spectral variations.
Abstract
Simultaneous temperature and relative humidity (RH) monitoring in storage environments remains challenging because polymer-coated fiber sensors often exhibit cross-sensitivity when demodulated from a single spectral feature. We report a compact reflection-type fiber Michelson interferometer with an end-face polyvinyl alcohol (PVA) film, in which a cascaded no-core fiber (NCF)/polarization-maintaining photonic-crystal fiber (PM-PCF) structure provides a feature-rich interference spectrum, while humidity-induced swelling and refractive-index changes of the PVA film produce measurable spectral variations. The selected probe achieved temperature sensitivities of 0.00727 nm/°C and -0.00504 dB/°C over 25-80 °C, and RH sensitivities of 0.04744 nm/%RH and -0.14120 dB/%RH over 48-84%RH. An additional RH cycling experiment at 23.7-24.2 °C yielded full-spectrum Pearson correlations of 0.9967-0.9990 and root-mean-square error (RMSE) values of 0.102-0.188 dB at low RH, supporting short-term optical reversibility. Full-spectrum ridge regression was evaluated by leave-one-condition-out validation across 33 measured coupled states, giving temperature and RH RMSE values of 1.9323 °C and 5.6935%RH, respectively, and improving on a fixed two-feature sensitivity-matrix baseline without using held-out labels. This result supports internal simultaneous demodulation feasibility within the measured conditions; increased uncertainty above 70%RH and the absence of external validation limit broader reliability claims.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fabry-Perot interferometric humidity sensor based on PVA-GQDs composite film.Applied optics · 2026
- Simulation and Experiment of Tilted Fiber Bragg Grating Humidity Sensor Coated with PVA/GO Nanofiber Films by ElectrospinningSensors · 2025
- Temperature-compensated air humidity measurement using a λ/2 coaxial resonator.The Review of scientific instruments · 2026
- Triple‐Cavity Cascaded FBG–FPI Hybrid Sensor for Simultaneous Temperature, Pressure, and Humidity Measurement With Sub‐1% Cross‐Sensitivity: A Numerical Design and Simulation StudyJournal of Sensors · 2026
- Full-Range Ultrasensitive Fiber-Optic Hydrogen Detection via Twin Vernier Amplification and Lightweight CNN.ACS sensors · 2026
- Self-temperature-compensated all-fiber refractive index sensor based on four-leaf clover fiber.Optics express · 2026